The magnetic field at the centre of the MCG is 0.25 T. The coil has an area of `0.2 m^2` and has 28 turns. If the sensitivity of the MCG is to be increased by 25%, thenumber of turns of the coil should be …….Assume all other things remaining constant

A

30

B

32

C

25

D

38

Text Solution

Verified by Experts

The correct Answer is:
C

`B=0.25T,A=0.2m^2,n_1=28,S_2=1.25S_1,n_2=?`
`S=(n AB)/(K)`
`therefore S prop n `
`(n_2)/(n_1)=(S_2)/(S_1)`
`n_2=(1.25S_1)/(S_1)xx n_1=1.25xx28=35`.
Promotional Banner

Topper's Solved these Questions

  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    NIKITA PUBLICATION|Exercise MCQs (Sensitivity and accuracy of M.C.G.)|1 Videos
  • KINETIC THEORY OF GASES & RADIATION

    NIKITA PUBLICATION|Exercise MCQs (Question Given in MHT-CET)|79 Videos
  • MAGNETISM

    NIKITA PUBLICATION|Exercise MCQs|249 Videos

Similar Questions

Explore conceptually related problems

The magnetic field at the centre of the M.C.G. is 0.25 T. The coil has an area of 0.2 m^(2) and has 28 turns. If the sensitivity of the M.C.G. is to be increased by 25%, the number of turns of the coil should be _______. Assume all other things remaining constant.

The magnetic field at the center of a moving coil galvanometer is 0.25 T. The coil has an area of 0.2 m^(2) and has 28 turns. If the current senstivity of the MCG is to be increased by 25%, then the number of turns in the coil should be incrased by_________.Assume that all other things are kept constant.

Magnetic field intensity at the centre of coil of 50 turns, radius 0.5m and carrying a current of 2A is

Magnetic field due to 0.1 A current flowing through a circular coil of radius 0.1 m and 1000 turns at the centre of the coil is

A current of 2 ampere is flowing through a coil of radius 0.1 m and having 10 turns. The magnetic moment of the coil will be :

A current of 2 ampere is passed in a coil of radius 0.5 m and number of turns 20.The magnetic moment of the coil is

A circular coil of 0.2 m diameter has 100 turns and carries a current of 0.1 ampere. The intensity of magnetic field at the centre of the coil is -

The sensitivity of a moving coil galvanometer can be increased by (1) decreasing the couple per unit twist of the suspension (2) increasing the number of turns in the coil (3) decreasing the area of the coil (4) decreasing the magnetic field