Home
Class 12
PHYSICS
In a transformer 220 ac voltage is incr...

In a transformer `220` ac voltage is increased to `2200` volts. If the number of turns in the secondary are `2000, then the number of turns in the primary will be

A

200

B

100

C

50

D

20

Text Solution

Verified by Experts

The correct Answer is:
A

`(n_(p))/(n_(S))=(e_(p))/(e_(S))`
`therefore n_(p)=(e_(p)*n_(S))/(e_(S))=(220xx2000)/(2200)=200`
Promotional Banner

Topper's Solved these Questions

  • ELASTICITY

    NIKITA PUBLICATION|Exercise MCQ|314 Videos
  • ELECTRONS AND PHOTONS

    NIKITA PUBLICATION|Exercise MCQs|162 Videos

Similar Questions

Explore conceptually related problems

A transformer steps an A.C voltage from 230 V ot 2300 V . If the number of turns in the secondary coil is 1000, the number of turns in the primary coil will be

A transformer steps up an A.C. voltage from 230 V to 2300 V. If the number of tunrs in the secondary coil is 1000, the number of turns in the primary coil will be

A transformer steps up in A.C voltage from 230V to "2300V" .If the number of turns in the secondary coil is "1000" ,the number of turns in the primary coil will

In a step down transformer, the number of turns in the primary is always

A step - up transformer is used on 120 V line to provide a potential difference of 2400 V . If the number of turns in the primary is 75, then the number of turns in the secondary shall be

In a step up transformers, 220V is converted into 200V . The number of turns in primary coil is 600 . What is the number of turns in the secondary coil?

The input voltage and output voltage in the primary and secondary coils of a transformer are 250 V and 5 V, respectively. If the number of turns in the primary coil of the transformer is 1000, find the number of turns in its secondary coil. Also mention, whether the transformer is a step-up one or a step-down one ?

In a step - down transformer the input voltage is 22kV and the output voltage is 550V The ratio of the number of turns in the secondary to that in the primary is .

NIKITA PUBLICATION-ELECTROMAGNETIC INDUCTION-MCQs
  1. Why are electromagnets made of soft iron?

    Text Solution

    |

  2. The transformation ratio in the step -up transformer is

    Text Solution

    |

  3. In a transformer 220 ac voltage is increased to 2200 volts. If the nu...

    Text Solution

    |

  4. The ratio of secondary to the primary turns in a transformer is 3:2. I...

    Text Solution

    |

  5. The primary winding of a transformer has 100 turns and its secondary w...

    Text Solution

    |

  6. A step-down transformer is connected to 2400 volts line and 80 amperes...

    Text Solution

    |

  7. A loss free transformer has 500 turns on its primary winding and 2500 ...

    Text Solution

    |

  8. An ideal transformer has 100 turns in the primary and 250 turns in the...

    Text Solution

    |

  9. The alternating voltage induced in the secondary coil of a transformer...

    Text Solution

    |

  10. We can reduce eddy currents in the core of transformer

    Text Solution

    |

  11. A 100% efficient transformer has 100 turns in the primary and 25 turns...

    Text Solution

    |

  12. The efficiency of transfomer is very high because

    Text Solution

    |

  13. In a lossless transformer an alternating current of 2 amp is flowing i...

    Text Solution

    |

  14. A transformer connected to 220 volt line shows an output of 2A at 1100...

    Text Solution

    |

  15. A power transformer is used to step up an alternating e.m.f. of 220 V ...

    Text Solution

    |

  16. A step up transformer connected to a 220V AC line is to supply 22 kV f...

    Text Solution

    |

  17. A transformer is employed to

    Text Solution

    |

  18. The number of turns in the primary coil of a transformer is 200 and th...

    Text Solution

    |

  19. A step-up transformer has transformation ratio of 3:2 what is the volt...

    Text Solution

    |

  20. A step-down transformer is connected to main supply 200V to operate a ...

    Text Solution

    |