Home
Class 12
PHYSICS
If numerical aperture of a microscope is...

If numerical aperture of a microscope is increased, then its

A

resolving power remains constant.

B

resolving power becomes zero

C

limit of resolution is decreased

D

limit of resolution in increased

Text Solution

Verified by Experts

The correct Answer is:
C

NA
Promotional Banner

Topper's Solved these Questions

  • INTERFERENCE AND DIFFRACTION

    TARGET PUBLICATION|Exercise EVALUATION TEST|20 Videos
  • INTERFERENCE AND DIFFRACTION

    TARGET PUBLICATION|Exercise CRITICAL THINKING|72 Videos
  • GRAVITATION

    TARGET PUBLICATION|Exercise EVALUATION TEST|24 Videos
  • KINETIC THEORY OF GASES AND RADIATION

    TARGET PUBLICATION|Exercise Evaluation test|18 Videos

Similar Questions

Explore conceptually related problems

The aperture of telescope is increases to

Numerical aperture of microscope lens is expressed by

Resolving power of a microscope is increased by

Calculated the numerical aperture of a microscope required to just resolve two points separated by a distance of 10^(-4) cm, using light of wavelength 5.8xx10^(-5)cm .

The limit of resolution of microscope, if the numerical aperture of microscope is 0.12 , and the wavelength of light used is 600 nm, is

The numerical aperture of a microscope is 0.31. If the wavelength of light used in 600 nm, calculate the resolving power of the microscope.

A microscope is used to resolved two objects placed at a distance of 2 xx 10^(-4) cm . Calculate the numerical aperture of the microscope if light of wavelength 6,000 Å is used.

TARGET PUBLICATION-INTERFERENCE AND DIFFRACTION-COMPETITIVE THINKING
  1. Red light of wavelength 625 nm is incident normally on a optical diffr...

    Text Solution

    |

  2. A telescope has an objective lens of 10cm diameter and is situated at ...

    Text Solution

    |

  3. If numerical aperture of a microscope is increased, then its

    Text Solution

    |

  4. In an astronomical telescope, the final image for normal vision is for...

    Text Solution

    |

  5. An astronomical refracting telescope will have large angular magnific...

    Text Solution

    |

  6. Resolving power of telescope increases when

    Text Solution

    |

  7. The ratio of resolving power of an optical microscope for two waveleng...

    Text Solution

    |

  8. Assume that light of wavelength 6000 Å is coming from a star. What is ...

    Text Solution

    |

  9. Diameter of the objective of a telescope is 200cm. What is the resolvi...

    Text Solution

    |

  10. The resolving power of a telescope whose lens has a diameter of 1.22 m...

    Text Solution

    |

  11. When a beam of light is used to determine the position of an object, t...

    Text Solution

    |

  12. Two slits at a distance of 1mm are illuminated by a light of wavelengt...

    Text Solution

    |

  13. In the Young's double slit experiment using a monochromatic light of w...

    Text Solution

    |

  14. In Young's double slit experiment, the fringe width obtained by a mono...

    Text Solution

    |

  15. If initial fringe width is X, the distance between screen and slits is...

    Text Solution

    |

  16. In Young's double slit experiment, one of the slit is wider than other...

    Text Solution

    |

  17. In Young's double slit experiment, the intensity on the screen at a po...

    Text Solution

    |

  18. In a Young's double slit experiment the intensity at a point where tha...

    Text Solution

    |

  19. In Young's double slit experiment, the two slits acts as coherent sour...

    Text Solution

    |

  20. The intensity at the maximum in a Young's double slit experiment is I0...

    Text Solution

    |