Home
Class 12
PHYSICS
A moving coild galvanometer of resistanc...

A moving coild galvanometer of resistance `20`Omega gives a full scale deflection when a current of 1mA is passed through it. It is to be converted into an ammeter reading 20A. But the resistance of the only shunt available is `0.005Omega`. What resistance should be connected in series with the galvanometer coil?

Promotional Banner

Similar Questions

Explore conceptually related problems

A moving coil galvanometer of resistance 20 Omega gives a full scale deflection when a current of 1mA is passed through it. It is to be converted into an ammeter reading 20 A on full scale. But the shunt of 0.005 Omega only is available. What resistance should be connected in series with the galvanometer coil?

A moving coil galvanometer of resistance 20 Omega gives a full scale deflection when a current of 1mA is passed through it. It is to be converted into an ammeter reading 20 A on full scale. But the shunt of 0.005 Omega only is available. What resistance should be connected in series with the galvanometer coil?

A moving coil galvanometer of resistance 20 Omega gives a full scale deflection when a current of 1mA is passed through it. It is to be converted into an ammeter reading 20 A on full scale. But the shunt of 0.005 Omega only is available. What resistance should be connected in series with the galvanometer coil?

A galvonometer of resistance 20 Omega gives a full scale deflection with a current of 0.04A is passed through it. It is derised to convert it into an ammeter of range 20A . The only shunt available is 0.05 Omega . The resistance that must be converted in series with the coil of the galvonometer is

A galvanometer of resistance 50Omega gives full scale deflection when a current 10^(-3)A is passed through it converted into an ammeter to measure 0.5A current.

A moving coil galvanometer of resistance 50 Omega gives a full scale deflection , when a current of 0.5 m A is passed through it. To convert it to a voltmeter of range , 10 V , the resistance required to be placed in series is

A moving coil galvanometer of resistance 10 ohm produces full scale deflection, when a current of 25 mA is passed through it. How will you convert the galvanometer into an ammeter reading upto 20 A.

A moving coil galvanometer of resistance 40 Omega gives full scales deflection when a current of 0.25 mA is paased through it. To convert it to voltmeter of range 10 V, the resistance requried to be placed in series is