Home
Class 12
PHYSICS
A battery of 12 V is connected to primar...

A battery of 12 V is connected to primary of a transformer with turns `n_(s) // n_(P) = 10`. Voltage across secondary would be

A

120 V

B

1.2 V

C

12 V

D

Zero

Text Solution

Verified by Experts

The correct Answer is:
D
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION & ALTERNATING CURRENT

    PRADEEP|Exercise JEE Mains Ad..(Multiple Choice Question)|1 Videos
  • ELECTROMAGNETIC INDUCTION & ALTERNATING CURRENT

    PRADEEP|Exercise Multiple Choice Questions|1 Videos
  • ELECTROMAGNETIC INDUCTION & ALTERNATING CURRENT

    PRADEEP|Exercise Value Based Questions|2 Videos
  • DUAL NATURE OF RADIATION AND MATTER

    PRADEEP|Exercise Exercise|191 Videos
  • ELECTROMAGNETIC WAVES

    PRADEEP|Exercise II Focus multiple choice question|5 Videos

Similar Questions

Explore conceptually related problems

In a step up transformer, the turn ratio is 3 : 2. A battery of EMF 4.5V is connected across the primary windings of transformer. The voltage developed in the secondary would be:

When a voltage of 120 V is impressed across the primary of a transformer, the current in the primary is 1.85 mA. Find the voltage across the secondary, when it delivers 150 mA. The transformer has an efficiency of 95 %.

A transformer is an electrical device which is used for changing the a.c. voltage. It is based on the phenomenon of mutual induction. It can be shown that (E_(s))/(E_(P)) = (I_(P))/(I_(s)) = (n_(s))/(n_(P)) = K Where the symbols have their standard meaning. For a step up transformer, K gt 1 and for a step down transformer, K lt 1 . The above relations are on the assumption that efficiency of transformer is 100% . In fact, efficiency eta = ("output power")/("input power") = (E_(s) I_(s))/(E_(P) I_(P)) The number of turns in the primary and secondary coils of a transformer are 2000 and 50 respectively. The primary coil is connected to main supply of 120 V and secondary to a night bulb 0.6 Omega . The efficiency of transformer is 80% . Voltage across the secondary coil of transformer is:

The primary and the secondary coils of a transformer contain 10 and 100 turns, respectively. The primary coil is connected to a battery that supplies a constant voltage of 1.5 volts. the voltage across the secondary coil is

If a dry cell of emf=1.5 V is connected across the primary of a step-up transformer of turn ratio 3:5, then calculate the voltage developed across the secondary.

The number of the turns in the primary coil of a transformer is 10 times than the same in the secondary coil . If the voltage across the primary is 20 V then find the voltage across the secondary .

The number of turns in the primary coil of a transformer are 100 and that in the secondary coil are 200. What type of transformer is it ? If the input voltage in the primary coil of the transformer is 200 V, find the output voltage in the secondary coil of the transformer.

The primary winding of a transformer has 100 turns and its secondary winding has 200V turns. The primary is connected to an ac supply of 120V and the current flowing in it is 10A . The voltage and the current in the secondary are

The input voltage and output voltage in the primary and secondary coils of a transformer are 250 V and 5 V, respectively. If the number of turns in the primary coil of the transformer is 1000, find the number of turns in its secondary coil. Also mention, whether the transformer is a step-up one or a step-down one ?

PRADEEP-ELECTROMAGNETIC INDUCTION & ALTERNATING CURRENT-Exercise
  1. A transformer is an electrical device used for

    Text Solution

    |

  2. The relation (E(s))/(E(P)) = (n(s))/(n(P)) is applicable only be

    Text Solution

    |

  3. A battery of 12 V is connected to primary of a transformer with turns ...

    Text Solution

    |

  4. Out of the following , choose the wrong statement :

    Text Solution

    |

  5. An a.c. generator is a machine that produces…………….from………………

    Text Solution

    |

  6. An a.c generator is based on the phenomenon of……………………………

    Text Solution

    |

  7. In hydroelectric power station,………………of falling water is converted int...

    Text Solution

    |

  8. A d.c. generator produces…………………from…………………

    Text Solution

    |

  9. In d.c. generator,…………………….generator of a.c. generator is replaced by…...

    Text Solution

    |

  10. A d.c. motor converts ………………………into ……………………….

    Text Solution

    |

  11. When a coil carrying current s …………………..it expericences ………………………….whi...

    Text Solution

    |

  12. In a.c. generator, we use……………………… to determine the direction of………………...

    Text Solution

    |

  13. In d.c. motor, we use……………………….to determine the direction of……………………..

    Text Solution

    |

  14. A transformer is an electrical device that is used for …………………. It ………...

    Text Solution

    |

  15. An a.c. generator consists of a coil of 100 turns and cross sectional ...

    Text Solution

    |

  16. An a.c. generator consists of a coil of 2000 turns each of area 80 cm^...

    Text Solution

    |

  17. A flat coil of 500 turns each of area 50 cm^(2) rotates in a uniform m...

    Text Solution

    |

  18. A coil has 50 turns and its area is 500 cm^(2). It is rotating at the ...

    Text Solution

    |

  19. A generator develops an e.m.f. of 120 V and has a terminal potential d...

    Text Solution

    |

  20. An a.c. generator consists of a coil of 50 turns and area 2.5 m^(2) ro...

    Text Solution

    |