Home
Class 12
PHYSICS
Ammeter is used for the measurement of...

Ammeter is used for the measurement of

A

current

B

potential difference

C

resistance

D

power

Text Solution

Verified by Experts

The correct Answer is:
A
Promotional Banner

Topper's Solved these Questions

  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    NIKITA PUBLICATION|Exercise MCQs (Sensitivity and accuracy of M.C.G.)|1 Videos
  • KINETIC THEORY OF GASES & RADIATION

    NIKITA PUBLICATION|Exercise MCQs (Question Given in MHT-CET)|79 Videos
  • MAGNETISM

    NIKITA PUBLICATION|Exercise MCQs|249 Videos

Similar Questions

Explore conceptually related problems

Fathometer is used to measure

A thermometer is used to measure

Assertion: when DC ammeter is used to measure current, then it measures average current flowing in the circuit . Reason : DC ammeter is based on heating effect of current .

An ac ammeter is used to measure currnet in a circuit. When a given direct current passes through the circuit. The ac ammeter reads 3 A. When another alternating current passes through the circuit, the ac ammeter reads 4A. Then find the reading of this ammeter (inA), if dc and ac flow through the circuit simultaneously.

Read the following text and answer the following questions on the basis of the same: Shunt resistance: The ammeter shunt is the device which provides the low resistance path to the flow of current. It is connected in parallel with the ammeter. In some ammeter the shunt is in-built inside the instrument while in others it is externally connected to the circuit. Manganin and Constantan are used for making the shunt of DC and AC ammeter respectively. Ammeters are designed for measurement of low current. For measuring high current, the shunt is connected in parallel to the ammeter. The significant portion of the current passes to the shunt because of the low resistance path and little amount of current passes through the ammeter. The shunt is connected in parallel to the ammeter because of which the voltage drops across the meter and shunt remain the same. Thus, the movement of the pointer is not affected by the shunt. Let us consider that the current to be measured is I. The circuit has ammeter and shunt connected parallel to each other. The ammeter is designed for measurement of small current say, I_(m) . The magnitude of the current I passes through the meter is very high, and it will burn the meter. So, for measuring the current I the shunt is required in the circuit. As the shunt connects in parallel with the ammeter, thus the same voltage drops occur between them: I_(Sh)R_(SH)=I_(m)R_(m) :.R_(SH)=I_(m)R_(m)//I_(SH) Shunt current I_(SH)=I-I_(m) So, R_(SH)=I_(m)R_(m)//(I-I_(m)) :.I//I_(m)=1+(R_(m)//R_(SH)) The ratio of the total current to the current required for the movement of the ammeter coil is called the multiplying power of the shunt. :. The multiplying power =m=I//L_(m) R_(SH)=R_(m)//(m-1) The following are the requirements of the shunt. • The resistance of the shunt should remain constant with time. • The temperature of the material-should remain same even though substantial current flows through the circuit. Materials used for making shunt of DC and AC ammeter are respectively

Hot wire ammeters are used for measuring

An ammeter gives full deflection when a current of 2 amp . Flows through it. The resistance of ammeter is 12 ohms . If the same ammeter is to be used for measuring a maximum current of 5 amp , then the ammeter must be connected with a resistance of

In an ammeter calibration experiment, the potentiometer is used to measure in the secondary circuit, the

NIKITA PUBLICATION-MAGNETIC EFFECT OF ELECTRIC CURRENT-MCQs (Sensitivity and accuracy of M.C.G.)
  1. Ammeter is used for the measurement of

    Text Solution

    |

  2. The sensitivity of a M.C.G. will increase if

    Text Solution

    |