A microammeter has as resistance of `100 Omega` and full scale range of `50 muA`. It can be used a voltmeter or as ahigher range ammeter provided a resistance is added to it. Pick the correct range and resistance combinations 50 V range with `10 kOmega` resistance in series b.`10 V` range with `200 kOmega` resistance in series c. 5mA rangw with `1Omega` resistance in parallel `10 mA` range with `1Omega` resistance in parallel
A
50 V range and `10 kOmega` resistance in series
B
10 V range and `200 k Omega` resistance in series
C
5 m A range with ` 1 Omega` resistance in parallel
D
both 'b' and 'c'
Text Solution
Verified by Experts
The correct Answer is:
D
(i) `R=(V)/(I_g)-G=(10)/(50xx10^-6)-100approx 200kOmega` For converting galvanometer into voltmeter a high resistance is joined in series with the galvanometer. (ii) `S=((I_g)/(I-I_g))G=((50xx10^-6)/(50xx10^-3-50xx10^-6))100approx1Omega` For converting galvanometer into ammeter a low resistance is joined in parallel with the galvanometer.
Topper's Solved these Questions
MAGNETIC EFFECT OF ELECTRIC CURRENT
NIKITA PUBLICATION|Exercise MCQs (Sensitivity and accuracy of M.C.G.)|1 Videos
KINETIC THEORY OF GASES & RADIATION
NIKITA PUBLICATION|Exercise MCQs (Question Given in MHT-CET)|79 Videos
MAGNETISM
NIKITA PUBLICATION|Exercise MCQs|249 Videos
Similar Questions
Explore conceptually related problems
A microameter has a resistance of 100 omega and a full scale range of 50 muA . It can be used as a voltmeter or as a higher range ammeter provides a resistance is added to it . Pick the correct range and resistance combination(s)
A micrometer has a resistance of 10Omega and a full scale range of 50muA . It can be used as a voltmeter or a higher range ammeter provided a resistance combination (s).
A microammeter has a resistance of 100W and a full scale range of 50 µA. It can be used as a voltmeter or a higher range ammeter provided a resistance is added to it. Pick the correct range and resistance combination(s). (1) 10V range with 200 kW resistance in series. (2) 50V range with 10 kW resistance in series. (3) 5 mA range with 1W resistance in parallel. (4) 10 mA range with 1 kW resistance in parallel.
A galvanometer has a resistance of 96Omega and full scale deflection of 100mu A. It can be used as ammeter provided a resistance is added to it. Pick up the correct range and resistance combination(s)
A micrometer has a resistance of 100 Omega and full scale deflection current of 50 muA . How can it be made to work as an ammeter of range 5mA ?
A galvanometer of internal resistance 100 Omega has a full scale deflection current of 1mA . To convert it into a voltmeter of range 0-10V , the resistance to be connected is
A galvanometer of internal resistance 100 Omega has a full scale deflection current of 1mA. To convert it into a voltmeter of range 0-10V, the resistance to be connected is
A range of galvanometer is V, when 50Omega resistance is connected in series. Its range gets doubled when 500Omega resistance is connected in series. Galvanometer resistance is
A galvanometer has a coil of resistance 100 Omega and gives a full scale deflection for 30 mA current. If it is to work as a voltmeter of 30 V range, the resistance required to be added will be.
NIKITA PUBLICATION-MAGNETIC EFFECT OF ELECTRIC CURRENT-MCQs (Sensitivity and accuracy of M.C.G.)