Home
Class 12
PHYSICS
A galvanometer with a full scale sensiti...

A galvanometer with a full scale sensitivity of 1 mA requires a `900 Omega` resistor to make a voltmeter reading full scale when 1 V is applied . What series resister is required to make the same galvanometer into 50 V full scale voltmeter ?

A

59000

B

49000

C

49900

D

4900

Text Solution

Verified by Experts

The correct Answer is:
C

`R_1=(V_1)/(I_g)-G therefore G=100Omega`
Now , `R_2=(V_2)/(I_g)-G=49,900Omega`.
Promotional Banner

Topper's Solved these Questions

  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    NIKITA PUBLICATION|Exercise MCQs (Sensitivity and accuracy of M.C.G.)|1 Videos
  • KINETIC THEORY OF GASES & RADIATION

    NIKITA PUBLICATION|Exercise MCQs (Question Given in MHT-CET)|79 Videos
  • MAGNETISM

    NIKITA PUBLICATION|Exercise MCQs|249 Videos

Similar Questions

Explore conceptually related problems

A moving coil galvanometer allows a full scale current of 10^-4A . A series resistance of 2mOmega is required to convert the above galvanometer into voltmeter of range 0-5 V. Therefore, the value of shunt resistance required to convert the above galvanometer into an ammeter of range 0-10 mA is:

A galvanometer having a coil resistance 200 Omega gives a full scale deflection when a current of 1mA is passed through it. What is the value of the resistance which can convert this galvanometer into a voltmeter giving full scale deflection for a potential difference of 50 V?

A moving coil galvanometer allows a full scale current of 10^(-4) A. A series resistance of 2 Momega is required to convert the above galvonometer into a voltmeter of range 0-5 V. Therefore the value of shunt resistance required to convert the above galvanometer into an ammeter of range 0-10 mA is:

A galvanometer of resistance 50Omega given full-scale deflection for a current of 10 mA is to be changed into a voltmeter of rang 100 V . What should be the Value of resistance to be added in series with this galvanometer ?

A galvanometer having a coil resistance 100 Omega given full scale deflection when a current of 1mA is passed throught it . What is the value of the resistance which can convert this galvanometer into a voltmeter giving full scale deflection for a potential difference of 10 V ?

The 80 Omega galvanometer deflects full scale for a potential of 20 mV. A voltmeter deflecting full scale of 5 V is to made using this galvanometer. We must connect

A galvanometer has a coil of resistance 100 Omega and gives a full scale deflection for 30 mA current. If it is to work as a voltmeter of 30 V range, the resistance required to be added will be.

A galvanometer has a coil of resistance 100 Omega and gives a full-scale deflection for 30 mA current. If it is to work as a voltmeter of 30 V range, the resistance required to be added will be

A galvanometer of resistance 20 ohm suffers full scale deflection for a current 20mA .It can be converted a Voltmeter of range 200V by