It is required to prepare a steel metre ...

It is required to prepare a steel metre scale, such that the millimetre intervals are to be ac curate within `0.0005 mm` at a certain temperature. Determine the maximum temperature variation allowable during the rulling of millimetre marks. Given, `alpha` for steel `=1.322xx10^(-5) .^(@)C^(-1)`

Promotional Banner

Similar Questions

Explore conceptually related problems

A steel metre scale is to be ruled so that the millimetre intervals are accurate to within about 5 xx 10^(-5) mm at a certain temperature. What is the maximum temperature variation allowable during the rulting ? Given alpha for steel = 1.1 xx 10^(-5).^(@)C^(-1) .

A steel metre scale is to be ruled so that the millimetre intervals are accurate to within about 5 xx 10^(-5) mm at a certain temperature. What is the maximum temperature variation allowable during the ruling ? Given alpha for steel = 1.1 xx 10^(-5).^(@)C^(-1) .

A steel metere scale isto be ruled so that the millimetre intervals are accurate within about 5xx10^(-5)mm at a certain temperature. What is the maximum temperature variation allowable during the ruling? ( alpha for steel =11xx10^(-6).^(@)C^(-1) )

A steel meter scale is to be ruled so that millimeter intervals are accurate within about 5xx10^(-5) mm at a certain temperature. The maximum temperature variation allowable during the ruling is (Coefficient of linear expansion of steel =10xx10^(-6)K^(-1) )

A steel meter scale is to be ruled so that millimetre intervals are accurate within about 5xx10^-5 m at a certain temperature. The maximum temperture variation allowable during the ruling is (coefficient of linear expansion of steel = 10xx10^-6K^-1

A steel scale is to be prepared such that the millimeter intervals are to be accurate within 6 xx10^(-5)mm . The maximum temperature variation form the temperature of calibration during the reading of the millimeter marks is (alpha = 12 xx 10^(-6)//"^(@)C)

A steel scale is to be prepared such that the millimeter intervals are to be accurate within 6 xx10^(-5)mm . The maximum temperature variation form the temperature of calibration during the reading of the millimeter marks is (alpha = 12 xx 10^(-6)//"^(@)C)

A steel scale is to be prepared such that the millimeter intervals are to be accurate within 6 xx10^(-5)mm . The maximum temperature variation form the temperature of calibration during the reading of the millimeter marks is (alpha = 12 xx 10^(-6)//"^(@)C)