Why is the meter bridge method considered unsuitable for the measurement of very low resistances ?
Text Solution
Verified by Experts
While measuring a vary low resistnace using meter bridge,all other resistances used should have low values in order to ensure sensitivity of the bridge. This requires the galvanometer should also be of very low resistances and a very sensitive. Then the end resistances and resistances of the connecting wires used in metre bridge bacoem comparable with the resistance to be measured. This would introduce error in the result. Due to it, the measurement will not be accurate.
Topper's Solved these Questions
CURRENT ELECTRICITY
PRADEEP|Exercise Conceptual Problems|3 Videos
CURRENT ELECTRICITY
PRADEEP|Exercise Very short Q/A|7 Videos
COMMUNICATION SYSTEMS
PRADEEP|Exercise MODEL TEST PAPER-2|9 Videos
DUAL NATURE OF RADIATION AND MATTER
PRADEEP|Exercise Exercise|191 Videos
Similar Questions
Explore conceptually related problems
Wheatstone bridge is not suitable for the measurement of resistance of the order of
Why is the meter bridge suitable for resistance of moderate values only ?
Wheatstone's bridge cannot be used for measurnment of very ………….. Resistance.
Triangulation method is used for measuring very long distances.
Make the appropriate connection in the meter bridge set up shown. Resistance box is connected between____. Unknown resistance is connected between_____. Battery is connected between_______.
In the circuit shown, a meter bridge is in its balanced state. The meter bridge wire has a resistance .1 ohm//cm . The value of unknown resistance X and the current drawn from the battery of negligible resistance is
PRADEEP-CURRENT ELECTRICITY-Problems for Practice (B)