Home
Class 12
PHYSICS
The coefficients of self induction of tw...

The coefficients of self induction of two coils are `L_(1)` and `L_(2)` .To induce an of `2` volt in the coil, a change of current of `1A` has to be produced in `5` second and `50ms` respectively. The ratio of their self inductances `L_(1):L_(2)` will be

A

`1:5`

B

`200:1`

C

`100:1`

D

`50:1`

Text Solution

Verified by Experts

The correct Answer is:
C
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    TARGET PUBLICATION|Exercise COMPETITIVE THINKING|158 Videos
  • ELECTROMAGNETIC INDUCTION

    TARGET PUBLICATION|Exercise EVALUATION TEST|8 Videos
  • ELECTROMAGNETIC INDUCTION

    TARGET PUBLICATION|Exercise EVALUATION TEST|8 Videos
  • ELASTICITY

    TARGET PUBLICATION|Exercise Evaluation test|14 Videos
  • ELECTROSTATICS

    TARGET PUBLICATION|Exercise EVALUATION TEST|14 Videos

Similar Questions

Explore conceptually related problems

The inductors of self inductance L_(1) and L_(2) are put in series .

The coefficients of self -induction of two coils are L_(1)=8mH and L_(2)=2mH respectively. The current rises in the two coils at the same rate . The power given to the two coils at any instant is same . The ratio of currents flowing in the coils will be

Coefficient of coupling between two coils of self-inductances L_(1) and L_(2) is unity. It means

Mutual inductance of two coils depends on their self inductance L_(1) and L_(2) as :

The self inductance of a coil is 5 henry , a current of 1 amp change to 2 amp within 5 second through the coil. The value of induced e.m.f. will be

The self induced emf of a coil is 25 volts. When the current in it is changed at uniformed rate from 10 A to 25 A in 1s, the change in the energy of the inductances is

If the rate of change of current is 1A per second in one coil induces an emf of 2 V in the neighbouring coil, the mutual inductance of two coils is

In Fig. coil 1 and coil 2 are wound on a long cylindrical insulator. The ends A' and B are joined together and current I is passed. Self-inductance of the two coils are L_(1) and L_(2) , and their mutual inductance is M . a. Show that this combination can be replaced by a single coil of equivalent inductange given by L_(eq) = L_(1) + L_(2) + 2M . b. How could the coils be reconnected by yieldings an equivalent inductance of L_(eq) = L_(1) + L_(2) - 2M .

Self-inductance of a coil is 50mH. A current of 1 A passing through the coil reduces to zero at steady rate in 0.1 s, the self-induced emf is

TARGET PUBLICATION-ELECTROMAGNETIC INDUCTION-CRITICAL THINKING
  1. A coil is wound as a transformer of rectangular cross section. If all ...

    Text Solution

    |

  2. When the current changes from +2A to -2A in 0.5 second an emf of 8V is...

    Text Solution

    |

  3. The coefficients of self induction of two coils are L(1) and L(2) .To ...

    Text Solution

    |

  4. When the number of turns in a coil is doubled without any change in th...

    Text Solution

    |

  5. A coil of wire of a certain radius has 600 turns and a self-inductance...

    Text Solution

    |

  6. The coefficients of self -induction of two coils are L(1)=8mH and L(2)...

    Text Solution

    |

  7. The coefficient of self-inductance of a solenoid is 0.18 mH. If a crud...

    Text Solution

    |

  8. A coil of self-inductance ((1)/(pi)) H is connected is series with a 3...

    Text Solution

    |

  9. The coefficient of mutual induction between two coils is 4H. If the cu...

    Text Solution

    |

  10. In a step up transformer, the input voltage is 300 V and the output vo...

    Text Solution

    |

  11. A transformer has 100 turns in the primary and 500 turns in the second...

    Text Solution

    |

  12. In a transformer 220 ac voltage is increased to 2200 volts. If the nu...

    Text Solution

    |

  13. The primary winding of a transformer has 100 turns and its secondary w...

    Text Solution

    |

  14. A loss free transformer has 500 turns on its primary winding and 2500 ...

    Text Solution

    |

  15. A step-down transformer is connected to 2400 volts line and 80 amperes...

    Text Solution

    |

  16. A 100% efficient transformer has 100 turns in the primary and 25 turns...

    Text Solution

    |

  17. The ratio of secondary to the primary turns in a transformer is 3:2. I...

    Text Solution

    |

  18. The number of turns in the primary coil of a transformer is 1000A. A p...

    Text Solution

    |

  19. In an A.C. generator, when the plane of the armature is perpendicular ...

    Text Solution

    |

  20. A coil of effective area 2m^(2) is rotated so as to cut a magnetic fie...

    Text Solution

    |