Home
Class 12
PHYSICS
An ideal transformer converts 220V a.c. ...

An ideal transformer converts `220V` a.c. to `3.3kV` a.c. to transmit a power of `4.4kW`. If primary coil has `600` turns, then alternating current in secondary coil is

A

`(1)/(3)A`

B

`(4)/(3)A`

C

`(5)/(3)A`

D

`(7)/(3)A`

Text Solution

Verified by Experts

The correct Answer is:
B
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    TARGET PUBLICATION|Exercise EVALUATION TEST|8 Videos
  • ELECTROMAGNETIC INDUCTION

    TARGET PUBLICATION|Exercise CRITICAL THINKING|84 Videos
  • ELASTICITY

    TARGET PUBLICATION|Exercise Evaluation test|14 Videos
  • ELECTROSTATICS

    TARGET PUBLICATION|Exercise EVALUATION TEST|14 Videos

Similar Questions

Explore conceptually related problems

An ideal transformer converts 220 V AC to 3.3 kV AC to transmit a power of 4.4 kW. If primary coil has 600 turns, then alternating current in secondary coil is

A power transformer is used to set up an alternating e.m.f of 220V to 4.4 kV to transmits 6.6 kW of power. The primary coil has 1000 turns. What is current rating of secondary? (Assume efficiency is 100%)

A power transformer is used to step up an alternating e.m.f. of 220 V to 11kv to trannsmit 4.4 kW of power. If the primary coil has 1000 turns, what is the current rating of the secondary?(Assume 100% efficiency for the transformer)

A transformer has turn ration 100//1 . If secondary coil has 4amp current then current in primary coil is

The number of turns in primary and secondary coils of a transformer is 50 and 200, respectively. If the current in the primary coil is 4 A, then current in the secondary coil is

In a step up transformers, 220V is converted into 200V . The number of turns in primary coil is 600 . What is the number of turns in the secondary coil?

TARGET PUBLICATION-ELECTROMAGNETIC INDUCTION-COMPETITIVE THINKING
  1. What is increase in step-down transformer?

    Text Solution

    |

  2. A transformer is used to light a 100 W and 110 V lamp from a 220V main...

    Text Solution

    |

  3. An ideal transformer converts 220V a.c. to 3.3kV a.c. to transmit a po...

    Text Solution

    |

  4. A transformer connected to 220 volt line shows an output of 2A at 1100...

    Text Solution

    |

  5. A 220 V input is supplied to a transformer. The output circuit draws a...

    Text Solution

    |

  6. A transformer has an efficiency of 80%. It works at 4 kW and 100 V. If...

    Text Solution

    |

  7. Assertion : A transformer cannot work on dc supply. Reason : dc chan...

    Text Solution

    |

  8. A step-down transformer has 50 turns on secondary and 1000 turns on pr...

    Text Solution

    |

  9. A step up transformer operates on a 230 V line and a load current of 2...

    Text Solution

    |

  10. A transformer having efficiency of 90% is working on 200 V and 3 kW po...

    Text Solution

    |

  11. The output of a step down transformer is measured to be 48V when conne...

    Text Solution

    |

  12. A coil has 2000 turns and area of 70cm^(2). The magnetic field perpen...

    Text Solution

    |

  13. In a region of uniform magnetic induction B=10^(2) tesla, a circular c...

    Text Solution

    |

  14. Alternating current can not be measured by D.C. Ammeter because

    Text Solution

    |

  15. If E(0) represents the peak value of the voltage in an ac circuit, the...

    Text Solution

    |

  16. The rms value of current in a 50Hz AC circuit is 6A. The average value...

    Text Solution

    |

  17. An alternating voltage E=200sqrt(2) sin (100 t)V is connected to a 1 m...

    Text Solution

    |

  18. A capacitor of capacitance 10muF is connected to an AC source and an A...

    Text Solution

    |

  19. The frequency of ac mains in India is

    Text Solution

    |

  20. The ratio of peak value and r.m.s value of an alternating current is

    Text Solution

    |