Home
Class 12
PHYSICS
Assertion: We can measure the potential ...

Assertion: We can measure the potential barrier of a `PN` junction by putting a sensitive voltmeter across its terminals.
Reason: The current through the `PN` junction is not same in forward and reversed bias.

A

Statement-1 is True, Statement-2 is True, Statement-2 is a correct explanation for Statement-1.

B

Statement-1 is True, Statement-2 is True, Statement-2 is NOT a correct explanation for Statement-1.

C

Statement -1 is False, Statement-2 is True.

D

Statement -1 is True, Statement-2 is False.

Text Solution

Verified by Experts

Promotional Banner

Topper's Solved these Questions

  • ROTATIONAL MOTION

    DISHA|Exercise physics|72 Videos
  • THERMAL EXPANSION AND CALORIMETRY

    DISHA|Exercise Physics|29 Videos

Similar Questions

Explore conceptually related problems

Can we measure the potential difference of a p-n junction by putting a sensitive voltmeter across its terminals?

The potential barrier at PN junction is due to

Assertion : We cannot meausre that potential barrier of p-n junction by putting a sensitive voltmeter across its terminals. Reason: In the depletion layer, there are no free elctrons or holes and in the absence of forward bias, it offers, infinite, resistance.

Can the potential barrier across a p-n junction be measured by simply connecting a voltmeter across the junction ?

p-n junction is a semiconductor diode. It is obtained by bringing p-type semiconductor inclose contact with n-type semiconductor. A thin layer is developed at the p-n junction which is devoid of any charge carrier but has immobile ions. It is called depletion layer. At the junction a potential barrier appears, which does not allow the movement of majority charge carriers across the junction in the absence of any biasing of the junction. p-n junction offer low resistance when forward biased and high resistance when reverse biased. Read the above paragaph and answer the following question: (i) Can we measure the potential barrier of p-n junction by putting a sensitive voltmeter across its terminals? (ii) What practical lesson do you draw from the above study?

Can the potential barrier across a p - n junction be measured by simply connecting a voltmeter across the junction ?

In forward bias, the width of potential barrier in a P-N junction diode

DISHA-SEMICONDUCTOR-physics
  1. At zero Kelvin a piece of germanium

    Text Solution

    |

  2. Electronical configuration of germenium is 2,8,18 and 4. To make it ex...

    Text Solution

    |

  3. The intrinsic semiconductor becomes an insulator at

    Text Solution

    |

  4. Energy band in solids are a consequence of

    Text Solution

    |

  5. In energy band diagram, the energy gap for carbon (diamond)is....... .

    Text Solution

    |

  6. The valence band and conduction band of a solid overlap at low temper...

    Text Solution

    |

  7. Choose the correct statement

    Text Solution

    |

  8. If n(e) and n(h) be the number of electrons and drift velocity in a se...

    Text Solution

    |

  9. The reverse biasing in a PN junction diode

    Text Solution

    |

  10. Two PN-junction can be connected in series by three different methods ...

    Text Solution

    |

  11. The approximate ratio of resistance in the forward and reverse biase o...

    Text Solution

    |

  12. The dominant mechanisms for motion of charge carriers in forward and r...

    Text Solution

    |

  13. In a triclinic crystal system

    Text Solution

    |

  14. The correct cymbol for zener diode is

    Text Solution

    |

  15. In the given figure, which of the diodes are forward biased?

    Text Solution

    |

  16. Which of the following materials are crystalline?

    Text Solution

    |

  17. A piece of copper and the other of germanium are cooled from the room ...

    Text Solution

    |

  18. Assertion: The number of electrons in a p-type silicon semiconductor i...

    Text Solution

    |

  19. Assertion: The resistivity of a semiconductor increases with temperatu...

    Text Solution

    |

  20. Assertion: We can measure the potential barrier of a PN junction by pu...

    Text Solution

    |