Home
Class 12
PHYSICS
A thermo couple uses Bismuth and Telluri...

A thermo couple uses Bismuth and Tellurium as the dissimilar metals. The sensitivity of bismuth is `-72 mu V//^(@)C` and that of the tellurium is `500 mu V//^(@)C`. If the difference between hot and cold junction is `100^(@)C` , then the maximum output will be

A

50 mV

B

`7.2 mV`

C

`42.8 mV`

D

`57.2 mV`

Text Solution

Verified by Experts

The correct Answer is:
D
Promotional Banner

Topper's Solved these Questions

  • HEATING AND CHEMICAL EFFECT OF CURRENT

    ERRORLESS |Exercise Heating Effect of Current|2 Videos
  • HEATING AND CHEMICAL EFFECT OF CURRENT

    ERRORLESS |Exercise Chemical Effect Current|1 Videos
  • ELECTROSTATICS

    ERRORLESS |Exercise Ordinary Thinking Objective Questions (Electric Flux and Gauss.s Law)|28 Videos
  • KINETIC THEORY OF GASES

    ERRORLESS |Exercise QUESTIONS|126 Videos

Similar Questions

Explore conceptually related problems

A thermocouple of resistance 1.6 Omega is connected in series with a galvanometer of 8 Omega resistance. The thermocouple develops and e.m.f. of 10 mu V per degree temperature difference between two junctions. When one junction is kept at 0^(@)C and the other in a molten metal, the galvanometer reads 8 millivolt . The temperature of molten metal, when e.m.f. varies linearly with temperature difference, will be

In the given circuit , the potential difference between A and B is 18 V and charge on 2 mu F capacitor is 24 mu C . The value of C is

A thermo couple develops 200 mu V between 0^(@)C and . 100^(@)C If it develops 64mu V and 76mu V respectively between (0^(@)C-32^(@)C) and (32^(@)C-70^(@)C) then what will be the thermo emf it develops between 70^(@)C and 100^(@)C

The 500 muF capacitor is charged at a steady rate of 100 mu C//s . The potential difference across the capacitor will be 10 V after an interval of

The temperature of the cold junction of thermo-couple is 0^(@)C and the temperature of hot junction is T^(@)C . The e.m.f . is E=16T-0.04 T^(2)mu volts. The temperature of inversion is

Thermocouples are used to measure temperature in the linear parts of the emf versus temperature graph wilth cold junction at 0^(@)C . The thermo electric power of Pt, Ni thermocouple are =-4 and -20 microcolt per .^(@)C respectively. What will be the magnitudes of emfs of the thermocopule when thecold junction is at 0^(@)C and the hot junction is at 100^(@)C ?

The charge stored in a capacitor is 20 mu C and the potential difference across the plates is 500V .Its capacity is ..?