Home
Class 12
PHYSICS
If a voltage to an X-ray tube is increas...

If a voltage to an X-ray tube is increased to 1.5 times the minimum wavelength `(lamda_(min))` of an X-ray continuous spectrum shifts by `Delta lamda = 26` pm. The initial voltage applied to the tube is

A

`~~ 10 kV`

B

`~~ 16 kV`

C

`~~ 50 kV`

D

`~~ 75kV`

Text Solution

Verified by Experts

The correct Answer is:
B
Doubtnut Promotions Banner Mobile Dark
|

Topper's Solved these Questions

  • ELECTRON, PHOTON, PHOTOELECTRIC EFFECT AND X-RAYS

    ERRORLESS |Exercise Assertion & Reason|3 Videos
  • ELECTRO MAGNETIC INDUCTION

    ERRORLESS |Exercise SET|20 Videos
  • ELECTRONICS

    ERRORLESS |Exercise Selv Evaluation Test|23 Videos

Similar Questions

Explore conceptually related problems

A voltage applied to an X -ray tube being increased eta = 1.5 times, the short-wave limit of an X -ray continuous spectrum shifts by Delta lambda = 26 pm . Find the initial voltage applied to the tube.

In the Coolidage tube experiment, if the applied voltage is increased to three times, the short wavelength limit of continuous X- ray spectrum shift by 20 pm. What is the intial voltage (in kV) applied to the tube?

Knowledge Check

  • The minimum wavelength lambda_min in the continuous spectrum of X-rays is

    A
    Proportional to the potential difference V between the cathode and anode.
    B
    Inversely proportional to potential differece V between the cathode and anode
    C
    Proportional to the square root of the potential difference V between the cathode and the anode.
    D
    Inversely proportional to the square root of the potential difference V between the cathode and the anode.
  • The voltage applied to the Coolidge X-ray tube is increased by 25%. As a result the short wave limit of continuous X-ray spectrum shifts by Delta lambda . The initial voltage applied to the tube is

    A
    `(hc)/(4e Delta lambda)`
    B
    `(hc)/(5e Delta lambda)`
    C
    `(4hc)/(5e Delta lambda)`
    D
    `(5hc)/(4e Delta lambda)`
  • An X-ray tube is operated at 50 kV. The minimum wavelength produced is

    A
    0.5 Å
    B
    0.75 Å
    C
    0.25 Å
    D
    1 Å
  • Similar Questions

    Explore conceptually related problems

    In the Coolidge tube experiment, if the applied voltage is increased to three times, the short wavelength limit of continuous X-ray spectrum shifts by 20 pm. What is the initial voltage (in kV) applied to the tube to the nearest integer value? [Take hc=12400 eV Å, e =1.6 xx 10^(-19)C ]

    In the Coolidge tube experiment if the applied voltage is increased to three times, the short wavelength limit of continuous X-ray spectrum shifts by 20 pm. What is the initial voltae (in kV) applied to the tube? [Round off your answer to the nearest integer]

    If the X–ray tube is working at 25 kV then the minimum wavelength of X–rays will be

    The voltage applied across an X-rays tube is nearly

    In a Coolidege tube experiment, the minimum wavelength of the continuouse X-ray spectrum is equal to 66.3 om . Then