Home
Class 12
PHYSICS
In a step - down transformer having prim...

In a step - down transformer having primary to secondary turn ratio `20:1` the input voltage applied is `250V` and output current is `8A` Assuming `100%` efficiency calculate the
(a) voltage across secondary coil
(b) current in primary coil
(c) power output .

Text Solution

Verified by Experts

The correct Answer is:
`(a) 12.5 V (b) 0.4 A (c ) 100 W`
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT

    PHYSICS GALAXY - ASHISH ARORA|Exercise Discussion Question-|21 Videos
  • ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT

    PHYSICS GALAXY - ASHISH ARORA|Exercise Conceptual MCQs|63 Videos
  • ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT

    PHYSICS GALAXY - ASHISH ARORA|Exercise Practice Exercise 5.6|8 Videos
  • CURRENT ELECTRICITY

    PHYSICS GALAXY - ASHISH ARORA|Exercise All Questions|389 Videos
  • ELECTROSTATICS

    PHYSICS GALAXY - ASHISH ARORA|Exercise Unsolved Numberical Problems|73 Videos

Similar Questions

Explore conceptually related problems

In a step-down transformer having primary to secondary turn ratio 10:1, the input voltage applied is 250V and outout current is 10 A. Assuming 100% efficiency, calculate the (i) voltage across secondary coil (ii) current in primary coil (iii) power output

An ideal step -up transformer has a primarycoil of 120 turns . The transformation ratio is 100 . If the input voltage and power are 230 V and 1000 W respectively, calculate (i) number of turns in the secondary coil . (ii) voltage across the secondary coil. (iii) current in the primary coil . (iv) current in the secondary coil. (v) power in the secondary coil.

The primary coil of an ideal stepup transformer has 100 turns and the transformer ratio is also 100. The input voltage and power are 220 V and 1100 W. Calculate (i) number of turns in secondary (ii) current in primary (iii) voltage across secondary (iv) current in secondary (v) power in secondary.

In a step up transformer, if ratio of turns of primary to secondary is 1:10 and primary voltage si 230 V . If the load current is 2A . Then the current in primary is

(i) Write the functions of a transformer . State its principle of working with the help of the a diagram mentions various energy losses in this divice . (ii) The primary coil of an ideal step up transformer has 100 turns and transformation ratio is also 100. The input voltage and power are respectively 220 V and 100w. Calculate (a) number of turns in secodary (b) current in primary ( c) voltage across secodary (d) current in secondary ( e) power in secondary

A transformer having efficiency of 80% is working on 200 V and 2 kW power supply. If the current in the secondary coil is 8A, the voltage across the secondary coil and the current in the primary coil respectively are

A transformer having efficiency of 90% is working on 200 V and 3 kW power supply. If the current in the secondary coil is 6A , the voltage across the secondary coil and current in the primary coil respectively are

Given the input current 15 A and input voltage of 100 V for a step up transformer having 90% efficiency. Find the output power and voltage in the secondary if output current is 3 A.