Home
Class 12
PHYSICS
A moving coil galvanometer has resistanc...

A moving coil galvanometer has resistance `50 Omega` and it indicates full deflection at 4 mA current. A voltmeter is made using this galvanometer and a `5 k Omega` resistance. The maximum voltage, that can be measured using this voltmeter (in volts) will be __________.

Text Solution

Verified by Experts

The correct Answer is:
20.2

`V=i_(g)[R_(g)+R]`
`=4xx10^(-3) [50+5000]=20.2 ` volt
Promotional Banner

Similar Questions

Explore conceptually related problems

A moving coil galvanometer has resistance 50 Omega and it indicates full deflection at 4 m A current. A voltmeter is made using this galvanometer and a 5k Omega resistance. The maximum voltmeter, will be close be :

A galvanometer of resistance 40 Omega gives the full scale deflection for a current of 10 m A through it. A resistance of 9960Omega is connected in series with the galvanometer coil. The mximum voltage that can be measured by the voltmeter is

A galvanometer has coil resistance 30 Omega and full deflection current of 2mA. What resistance is needed to convert it into a voltmeter of 0.2V range.

A galvanometer with a coil of resistance 50 Omega shows full-scale deflection when 10 mA current passes through it.

A moving coil galvanometer has a resistance of 50 Omega and gives full scale deflection for 10 mA . How could it be converted into an ammeter with a full scale deflection for 1 A

A moving coil galvanometer of resistance 5 Omega has voltage sensitivity 2 div per mV. Its current sensitivity in div per mA is

A galvanometer has a coil of resistance 100 Omega and gives a full-scale deflection for 30 mA current. If it is to work as a voltmeter of 30 V range, the resistance required to be added will be