Home
Class 10
PHYSICS
(a) What current is taken by a 3 kW elec...

(a) What current is taken by a 3 kW electric geyser working on 240 V mains ?
(b) What size fuse should be used in the geyser circuit ?

Text Solution

Verified by Experts

The correct Answer is:
N/a

(a) 12.5 A (b) 13 A fuse
Promotional Banner

Topper's Solved these Questions

  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    LAKHMIR SINGH & MANJIT KAUR|Exercise LONG ANSWER TYPE QUESTIONS|2 Videos
  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    LAKHMIR SINGH & MANJIT KAUR|Exercise QUESTIONS BASED ON HIGH ORDER THINKING SKILLS|6 Videos
  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    LAKHMIR SINGH & MANJIT KAUR|Exercise NCERT BOOK|2 Videos
  • ELECTRICITY

    LAKHMIR SINGH & MANJIT KAUR|Exercise NCERT|3 Videos
  • REFLECTION OF LIGHT

    LAKHMIR SINGH & MANJIT KAUR|Exercise Very Short Answer Type Questions|1 Videos

Similar Questions

Explore conceptually related problems

What is the function of a fuse in the domestic electric circuit?

A 1.25 kW heater works on a 220 V mains supply. What current rating would a suitable fuse have ?

(a) Why are fuses fitted in the fuse box of a domestic electricity supply ? (b) What device could be used in place of the fuses ?

For driving a current of 3 A for 5 minutes is an electric circuit, 900 J of work is to be done. Find the emf of the source in the circuit.

An electric heater is rated at 2 kW. Electrical energy costs Rs 4 per kWh. What is the cost of using the heater for 3 hours?

(a) Are electrons consumed in a electric circuit when a current flows through it ? (b) What actually is consumed in an electric circuit when current flows through it ?

The currents in the parts of an electric circuit. What is the value of I ?

LAKHMIR SINGH & MANJIT KAUR-MAGNETIC EFFECT OF ELECTRIC CURRENT -Exercise
  1. (a) An electric iron is rated at 230 V, 750 W. Calculate (i) the maxim...

    Text Solution

    |

  2. What is the function of an earth wire? Why is it necessary to earth me...

    Text Solution

    |

  3. (a) What current is taken by a 3 kW electric geyser working on 240 V m...

    Text Solution

    |

  4. A 1.25 kW heater works on a 220 V mains supply. What current rating wo...

    Text Solution

    |

  5. The maximum number of 40 W tube-lights connected in parallel which can...

    Text Solution

    |

  6. In normal use, a current of 3.5 A flows through a hair dryer. Choose a...

    Text Solution

    |

  7. Which one of the following statements is not true ?

    Text Solution

    |

  8. A car headlamp of 48 W works on the car battery of 12 V. The correct f...

    Text Solution

    |

  9. A 3-pin mains plug is fitted to the cable for a 1 kW electric kettle t...

    Text Solution

    |

  10. A T.V. set consumes an electric power of 230 watts and runs on 230 vol...

    Text Solution

    |

  11. An MCB which cuts off the electricity supply in case of short-circuiti...

    Text Solution

    |

  12. An air-conditioner of 3.2 kW power rating is connected to a domestic e...

    Text Solution

    |

  13. Three appliances are connected in parallel to the same source which pr...

    Text Solution

    |

  14. A vaccum cleaner draws a current of 2 A from the mains supply (a) Wh...

    Text Solution

    |

  15. An electric kettle rated as 1200 W at 220 V and a toaster rated at 100...

    Text Solution

    |

  16. What is the main difference in the wiring of an electric bulb and a so...

    Text Solution

    |

  17. A domestic lighting circuit has a fuse of 5 A. If the mains supply is ...

    Text Solution

    |

  18. Why does a compass needle get deflected when brought near a bar magnet...

    Text Solution

    |

  19. Draw magnetic field lines around a bar magnet.

    Text Solution

    |

  20. List the properties of magnetic lines of force.

    Text Solution

    |