Home
Class 10
PHYSICS
An electric kettle rated as 1200 W at 22...

An electric kettle rated as 1200 W at 220 V and a toaster rated at 1000 W at 220 V are both connected in parallel to a source of 220 V. If the fuse connected to the source blows when the current exceeds. 9.0 A, can both appliances be used at the same time ? Illustrate your answer with calculations.

Text Solution

AI Generated Solution

The correct Answer is:
To determine whether both the electric kettle and the toaster can be used at the same time without blowing the fuse, we will perform the following calculations step by step. ### Step 1: Calculate the total power of the appliances The electric kettle has a power rating of 1200 W and the toaster has a power rating of 1000 W. Since they are connected in parallel, the total power (P_total) can be calculated as: \[ P_{\text{total}} = P_{\text{kettle}} + P_{\text{toaster}} = 1200 \, \text{W} + 1000 \, \text{W} = 2200 \, \text{W} \] ### Step 2: Calculate the total current drawn by the appliances Using the formula for power, we can find the total current (I_total) drawn by the appliances when connected to a voltage of 220 V. The formula relating power (P), voltage (V), and current (I) is: \[ P = V \times I \] Rearranging this gives: \[ I = \frac{P}{V} \] Substituting the values we have: \[ I_{\text{total}} = \frac{P_{\text{total}}}{V} = \frac{2200 \, \text{W}}{220 \, \text{V}} = 10 \, \text{A} \] ### Step 3: Compare the total current with the fuse rating The fuse connected to the source blows when the current exceeds 9.0 A. From our calculation, the total current drawn by both appliances is 10 A. Since 10 A exceeds the fuse rating of 9 A, the fuse will blow if both appliances are used at the same time. ### Conclusion Both the electric kettle and the toaster cannot be used at the same time without blowing the fuse. ---

To determine whether both the electric kettle and the toaster can be used at the same time without blowing the fuse, we will perform the following calculations step by step. ### Step 1: Calculate the total power of the appliances The electric kettle has a power rating of 1200 W and the toaster has a power rating of 1000 W. Since they are connected in parallel, the total power (P_total) can be calculated as: \[ P_{\text{total}} = P_{\text{kettle}} + P_{\text{toaster}} = 1200 \, \text{W} + 1000 \, \text{W} = 2200 \, \text{W} \] ...
Promotional Banner

Topper's Solved these Questions

  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    LAKHMIR SINGH & MANJIT KAUR|Exercise LONG ANSWER TYPE QUESTIONS|2 Videos
  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    LAKHMIR SINGH & MANJIT KAUR|Exercise QUESTIONS BASED ON HIGH ORDER THINKING SKILLS|6 Videos
  • MAGNETIC EFFECT OF ELECTRIC CURRENT

    LAKHMIR SINGH & MANJIT KAUR|Exercise NCERT BOOK|2 Videos
  • ELECTRICITY

    LAKHMIR SINGH & MANJIT KAUR|Exercise NCERT|3 Videos
  • REFLECTION OF LIGHT

    LAKHMIR SINGH & MANJIT KAUR|Exercise Very Short Answer Type Questions|1 Videos

Similar Questions

Explore conceptually related problems

A 25 W , 220 V bulb and a 100 W , 220 V bulb are connected in parallel across a 440 V line

If two identical heaters each rated as (1000 W, 220 V) are connected in parallel to 220 V, then the total power consumed is

Two bulbs, one rated 100 W at 220 V and other 200 W at 220 V are connected In series In parallel to the electric main supply of 220 V. Find the current drawn in each case.

If two identical heaters each rated as (1000 W, 220V) are connected are connected in parallel to 220 V, then the total power consumed is .

A bulb of 40 W is connected across a source of 220 V . Find the resistance of the bulb.

If a bulb of 60 W is connected across a source of 220 V, find the current drawn by it.

Three appliances are connected in parallel to the same source which provides a voltage of 220 V. A fuse connected to the source will blow if the current from the source exceeds 10 A. If the three appliances are rated at 60 W, 500 W and 1200 W at 220 V, will the fuse blow ?

LAKHMIR SINGH & MANJIT KAUR-MAGNETIC EFFECT OF ELECTRIC CURRENT -Exercise
  1. Three appliances are connected in parallel to the same source which pr...

    Text Solution

    |

  2. A vaccum cleaner draws a current of 2 A from the mains supply (a) Wh...

    Text Solution

    |

  3. An electric kettle rated as 1200 W at 220 V and a toaster rated at 100...

    Text Solution

    |

  4. What is the main difference in the wiring of an electric bulb and a so...

    Text Solution

    |

  5. A domestic lighting circuit has a fuse of 5 A. If the mains supply is ...

    Text Solution

    |

  6. Why does a compass needle get deflected when brought near a bar magnet...

    Text Solution

    |

  7. Draw magnetic field lines around a bar magnet.

    Text Solution

    |

  8. List the properties of magnetic lines of force.

    Text Solution

    |

  9. Why don't two magnetic field lines intersect each other?

    Text Solution

    |

  10. Consider a circular loop of wire lying in the plane of the table. Let ...

    Text Solution

    |

  11. The magnetic field in a given region is uniform. Draw a diagram to rep...

    Text Solution

    |

  12. Choose the correct option: The magnetic field inside a long straight...

    Text Solution

    |

  13. Which of the following properties of a proton can change while it move...

    Text Solution

    |

  14. A positively-charged particle (alpha particle) projected towards west ...

    Text Solution

    |

  15. State Fleming's left-hand rule.

    Text Solution

    |

  16. What is the principle of an electric motor?

    Text Solution

    |

  17. What is the role of the split-ring in an electric motor?

    Text Solution

    |

  18. Explain different ways to induce current in a coil.

    Text Solution

    |

  19. State the principle of an electric generator.

    Text Solution

    |

  20. Name some sources of direct current.

    Text Solution

    |