Home
Class 12
PHYSICS
The true statement for thermo e.m.f . of...

The true statement for thermo e.m.f . of a thermocouple

A

depends on the nature of metals

B

depends only on temperature of cold junction

C

depends only on temperature of hot junction

D

depends on the length of the wires used for thermocouple

Text Solution

Verified by Experts

Promotional Banner

Topper's Solved these Questions

  • CIRCULAR MOTION

    ALLEN|Exercise EXERCISE (J-A)|6 Videos
  • GEOMETRICAL OPTICS

    ALLEN|Exercise subjective|14 Videos

Similar Questions

Explore conceptually related problems

Above neutral temperature, thermo e.m.f. in a thermocouple

The expression for thermo emf in a thermocouple given by the relation E=40theta-(theta^(2))/(20) , where theta is the temperatue difference of two junctons. For this, the neutral temperature will be

The thermo e.m.f E in volts of a certain thermocouple is found to very with temperature difference theta in ""^(@)C between the two junctions according to the relation E = 30 theta - (theta^(2))/(15) . The neutral temperatur e for the thermo - couple will be .

The thermo e.m.f. E in volts of a certain thermocouple is found to vary with temperature difference q in .^(@)C between the two junctions according to the relation E=30 theta-(theta^(2))/(15) The neutral temperature for the thermo-couple will be:-

The thermo e.m.f. of a thermo- couple is 25 muV//^@C at room temperature. A galvanometer of 40 ohm resistance, capable of detecting current as low as 10^(-5) A, is connected with the thermo couple. The smallest temperature difference that can be detected by this system is

The rate of increase of thermo-emf with temperature at the neutral temperature of a thermocouple

The thermo emf E (in volts) of a certain thermocouple is found to vary with Q (in C) acoording to eqution (E=20Q-Q^2/(20)) , where Q is tempereature of the hot function, the cold function being kept at 0^@C . Then the neutral temperature of the thermocouple is

Assertion : When temperature of cold junction of a thermocouple is lowered, the value of neutral temperature of this thermocouple is raised. Reason : When the difference of temperature of two junction is raised, more thermo e.m.f. is produced.

The thermo emf E of a thermocouple is found to vary wit temperature T of the junction (cold junction is 0^(@)C ) as E=40T-(T^(2))/(20) The temperature of inversion for the thermocouple is

Assertion: When temperature of cold junction of a thermocouple is lowered, the value of neutral temperature of this thermo couple is raised. Reason: When the difference of temperature of two junction is raised. More thermo emf is produced.

ALLEN-CURRENT ELECTRICITY-All Questions
  1. The amount of substance liberated on electrodes during electrolysis wh...

    Text Solution

    |

  2. All bulbs in figure below are identical which, bulbs light most bright...

    Text Solution

    |

  3. The true statement for thermo e.m.f . of a thermocouple

    Text Solution

    |

  4. Your are given resistance wire of length 50 cm and a battery of neglig...

    Text Solution

    |

  5. A factory is served by a 220 V supply line. In a circuit protected by ...

    Text Solution

    |

  6. A copper refining cell consists of two parallel copper plate electrode...

    Text Solution

    |

  7. The resistance of hot tungsten filament is about 10 times the cold res...

    Text Solution

    |

  8. The temperature of cold junction and neutral temperature of a thermoco...

    Text Solution

    |

  9. A wire of length L and 3 identical cells is now connected in series wi...

    Text Solution

    |

  10. A thermocouple is made of Cu and Fe . If a battery is connected in it,...

    Text Solution

    |

  11. A steady current is passed for 25minutes through a silver voltameter a...

    Text Solution

    |

  12. Two resistance connected in parallel across a cell of negligible inter...

    Text Solution

    |

  13. If the temperature of cold junction of thermocouple is lowered, then t...

    Text Solution

    |

  14. Silver and copper voltmeters are connected in parallel with a battery ...

    Text Solution

    |

  15. The amount of charge required to liberate 9 gm of aluminium (atomic we...

    Text Solution

    |

  16. A fuse wire with a circular cross-section and having a diam eter of 0....

    Text Solution

    |

  17. For a thermocouple, the neutral temperature is 270^(@)C and the temper...

    Text Solution

    |

  18. The internal resistance of primary cell is 4Omega it genrater a curren...

    Text Solution

    |

  19. Water can not be made conducting by adding small am ount of any of the...

    Text Solution

    |

  20. For goldplating on a copper chain, the substance required in the form ...

    Text Solution

    |