Home
Class 12
PHYSICS
For a thermocouple, the neutral temperat...

For a thermocouple, the neutral temperature is `270^(@)C` and the temperature of its cold junction is `20^(@)C` . If there is no deflection in the galvanometer, the temperature of the hot junction should be

A

`210^(@)C`

B

`540^(@)C`

C

`520^(@)C`

D

`209^(@)C`

Text Solution

Verified by Experts

Promotional Banner

Topper's Solved these Questions

  • CIRCULAR MOTION

    ALLEN|Exercise EXERCISE (J-A)|6 Videos
  • GEOMETRICAL OPTICS

    ALLEN|Exercise subjective|14 Videos

Similar Questions

Explore conceptually related problems

Do all the thermocouples have a neutral temperature?

In a thermocouple, the temperature that does not depend on the temperature of the cold junction is called

For a thermocouple the neutral temperature is 270^(@)C when its cold junction is at 20^(@)C . What will be the neutral temperature and the temperature of inversion when the temperature of cold junction is increased to 40^(@)C

For a thermocouple , the inversion temperature is 600^(@)C and the neutral temperature is 320^(@)C . Find the temperature of the cold junction ?

Consider the following statements regarding a thermocouple. (A) The neutral temperature does not depend on the temperature of the cold junction. (B) The inversion temperature does not depend on the temperature of the cold junction.

If for a thermocouple T_(n)) is the neutral temperature, T_(c ) is the tempreture of the cold junction and T_(i)) is the temperature of inversion, then

The emf of a thermocouple changes sign at 600 K. If the nertral temperature is 210^(@)C , what is the temperature of cold junction?

As the temperature of hot junction increases, the thermo e.m.f.

If the temperature of cold junction of thermocouple is lowered, then the neutral temperature

ALLEN-CURRENT ELECTRICITY-All Questions
  1. The amount of charge required to liberate 9 gm of aluminium (atomic we...

    Text Solution

    |

  2. A fuse wire with a circular cross-section and having a diam eter of 0....

    Text Solution

    |

  3. For a thermocouple, the neutral temperature is 270^(@)C and the temper...

    Text Solution

    |

  4. The internal resistance of primary cell is 4Omega it genrater a curren...

    Text Solution

    |

  5. Water can not be made conducting by adding small am ount of any of the...

    Text Solution

    |

  6. For goldplating on a copper chain, the substance required in the form ...

    Text Solution

    |

  7. The same mass of copper is drawn into two wires 2 mm and 3mm thick. Th...

    Text Solution

    |

  8. Peltier co-efficient of a thermo couple is 2 nano volts. How much heat...

    Text Solution

    |

  9. Arrange the power consumed in the given circuits in decreasing order (...

    Text Solution

    |

  10. The thermo emf of a therocouple , one junction of which is kept at 0^(...

    Text Solution

    |

  11. One junction of a certain thermoelectric couple is at a fixed temperat...

    Text Solution

    |

  12. Above neutral temperature, thermo e.m.f. in a thermocouple

    Text Solution

    |

  13. Assertion: Two electric bulbs of 50 and 100W. Are given. When connect...

    Text Solution

    |

  14. Assertion: If lamp B or C fuses then light emitted by lamp A decrease...

    Text Solution

    |

  15. Assertion: Heat is generated continoulsy in an electric heater but its...

    Text Solution

    |

  16. Assertion: The possibility of an electric bulb fusing is higher at the...

    Text Solution

    |

  17. Assertion: Fuse wire must have high resistance and low melting point. ...

    Text Solution

    |

  18. Assertion: When temperature of cold junction of a thermocouple is lowe...

    Text Solution

    |

  19. Assertion: Neutral temperature of a thermocuple does not depend upon t...

    Text Solution

    |

  20. Assertion: Current is passed through a metallic wire, heating it red. ...

    Text Solution

    |