Home
Class 12
PHYSICS
Assertion: When temperature of cold junc...

Assertion: When temperature of cold junction of a thermocouple is lowered, the value of neutral temperature of this thermo couple is raised.
Reason: When the difference of temperature of two junction is raised. More thermo emf is produced.

A

If both Assertion `&` Reason are True `&` the Reason is a correct explanantion of the Assertion

B

If both Assertion `&` Reason True but Reason is not a correct explanation of the Assertion

C

If Assertion is True but the Reason is False

D

If both Assertion `&` Reason are False.

Text Solution

Verified by Experts

Promotional Banner

Topper's Solved these Questions

  • CIRCULAR MOTION

    ALLEN|Exercise EXERCISE (J-A)|6 Videos
  • GEOMETRICAL OPTICS

    ALLEN|Exercise subjective|14 Videos

Similar Questions

Explore conceptually related problems

Assertion : When temperature of cold junction of a thermocouple is lowered, the value of neutral temperature of this thermocouple is raised. Reason : When the difference of temperature of two junction is raised, more thermo e.m.f. is produced.

If the temperature of cold junction of thermocouple is lowered, then the neutral temperature

As the temperature of hot junction increases, the thermo e.m.f.

Above neutral temperature, thermo e.m.f. in a thermocouple

As the temperature of hot junction of a thermo-couple is increased (while cold junction is at constant temperature), the thermo e.m.f .

The rate of increase of thermo-emf with temperature at the neutral temperature of a thermocouple

For a thermocouple, the temperature of inversion is that temperature at which thermo e.m.f. is

In a thermocouple, the temperature that does not depend on the temperature of the cold junction is called

The temperature of inversion of a thermocouple is 620^(@)C and the neutral temperature is 300^(@)C . What is the temperature of cold junction?

ALLEN-CURRENT ELECTRICITY-All Questions
  1. The thermo emf of a therocouple , one junction of which is kept at 0^(...

    Text Solution

    |

  2. One junction of a certain thermoelectric couple is at a fixed temperat...

    Text Solution

    |

  3. Above neutral temperature, thermo e.m.f. in a thermocouple

    Text Solution

    |

  4. Assertion: Two electric bulbs of 50 and 100W. Are given. When connect...

    Text Solution

    |

  5. Assertion: If lamp B or C fuses then light emitted by lamp A decrease...

    Text Solution

    |

  6. Assertion: Heat is generated continoulsy in an electric heater but its...

    Text Solution

    |

  7. Assertion: The possibility of an electric bulb fusing is higher at the...

    Text Solution

    |

  8. Assertion: Fuse wire must have high resistance and low melting point. ...

    Text Solution

    |

  9. Assertion: When temperature of cold junction of a thermocouple is lowe...

    Text Solution

    |

  10. Assertion: Neutral temperature of a thermocuple does not depend upon t...

    Text Solution

    |

  11. Assertion: Current is passed through a metallic wire, heating it red. ...

    Text Solution

    |

  12. Assertion: In parallel combination of electrical appliances, total pow...

    Text Solution

    |

  13. Assertion: A domestic electric appliance, working on a three pin will ...

    Text Solution

    |

  14. Assertion: Thermocouple acts as a heat engine. Reason: When two jun...

    Text Solution

    |

  15. Assertion: The 200 W bulb glows with more brightness than 100W bulbs. ...

    Text Solution

    |

  16. Assertion: Through the same current flows through the line wires and t...

    Text Solution

    |

  17. Assertion: In series combination of electric bulbs th ebulb of lower p...

    Text Solution

    |

  18. Assertion: The presence of water molecules makes separation of ions ea...

    Text Solution

    |

  19. Assertion: In practical application, power rating of resistance is no...

    Text Solution

    |

  20. Assertion: In all conductors, for studying the thermoelectric behaviou...

    Text Solution

    |