Home
Class 12
PHYSICS
What is a reduction factor of tangent ga...

What is a reduction factor of tangent galvanometer and its unit of measurement?

A

`Am^(2)`

B

`Am`

C

`A`

D

`Am^(-1)`

Text Solution

Verified by Experts

The correct Answer is:
C
Promotional Banner

Topper's Solved these Questions

  • MAGNETISM AND MATTER

    AAKASH INSTITUTE|Exercise ASSIGNMENT (SECTION A)|34 Videos
  • MAGNETISM AND MATTER

    AAKASH INSTITUTE|Exercise ASSIGNMENT (SECTION B)|21 Videos
  • MAGNETISM AND MATTER

    AAKASH INSTITUTE|Exercise Assignment Section D (Assertion- Reason Type Questions)|8 Videos
  • LAWS OF MOTION

    AAKASH INSTITUTE|Exercise Assignment (SECTION-D) (Assertion-Reason Type Questions)|15 Videos
  • MECHANICAL PROPERTIES OF FLUIDS

    AAKASH INSTITUTE|Exercise SECTION - J|9 Videos

Similar Questions

Explore conceptually related problems

The unit of reduction factor of tangent galvanometer is

Tangent galvanometer is used to measure

Tangent galvanometer mearusre

The reduction factor K of a tangent galvanometer is written on the instrument. The manual says that the current is obtained by multiplying this factor to tantheta . The procedure works well at Bhuwaneshwar. Will the procedure work if the instrument is taken to Nepal? If there is some error, can it be corrected by correcting the manual or the instrument will have to be taken back to the factory?

State tangent law in magnetism. How will the reduction factor of a tangent galvanometer change when the number of turns of its coil is doubled? Explain.

The reduction factor of a tangent galvanometer may be defined as the current passing through it to produce a deflection of

Accuracy of tangent galvanometer maximum at

AAKASH INSTITUTE-MAGNETISM AND MATTER -EXERCISE
  1. A magnetic dipole of magnetic moment 1.44 A m^2 is placed horizontally...

    Text Solution

    |

  2. The time period of a vibration magnetometer is T(0). Its magnet is rep...

    Text Solution

    |

  3. The length of a magnet is large compared to its width and breadth. The...

    Text Solution

    |

  4. A defiection magnetometer works on

    Text Solution

    |

  5. The arms of a deflection magnetometer in tangent B position are placed...

    Text Solution

    |

  6. The deflection magnetometer is most sensitive when the defiection the...

    Text Solution

    |

  7. Two short magnet having magnetic moment in the ratio 27:8, when placed...

    Text Solution

    |

  8. To work with a tangent galvanometer, how do you set its coil?

    Text Solution

    |

  9. What is a reduction factor of tangent galvanometer and its unit of mea...

    Text Solution

    |

  10. The number of turns and radius of cross-section of the coil of a tange...

    Text Solution

    |

  11. Two tangent galvanometer A and B are identical except in their number ...

    Text Solution

    |

  12. A magnetising field of 2xx10^(3)Am^(-1) produces a magnetic flux densi...

    Text Solution

    |

  13. The universal proporty among all substance is

    Text Solution

    |

  14. The magnetic susceptibility of a paramagnetic material at -73^(@)C "is...

    Text Solution

    |

  15. Liquid oxygen remains suspended between two pole faces of a magnet bec...

    Text Solution

    |

  16. Domain formation is the necessary feature of

    Text Solution

    |

  17. Susceplibility of a magnetic substance is found to depend on temperatu...

    Text Solution

    |

  18. The hysteresis curve is generally studied in the case of

    Text Solution

    |

  19. The variation of magnetic susceptibility (chi) with absolute temperatu...

    Text Solution

    |

  20. If the magnetic dipole of moment of an atom of diamagnetic material, p...

    Text Solution

    |