The deposition of lipids on the wall lining the lumen of large and medium sized arteries is referred to as
The deposition of lipids on the wall lining the lumen of large and medium sized arteries is referred to as
Similar Questions
Explore conceptually related problems
These questions consist of two statement each, printed as Assertion and Reason. While answering these questions, you are required to choose any one of the following four responses. A. If both Assertion and Reason are true and Reason is a correct explanation of the Assertion. B. If both Assertion and Reason are true but Reason is not a correct explanation of the Assertion. C. If Assertion is true but Reason is false. D. If both Assertion and Reason are false. Assertion: There is large deposition of lignin in the lumen of tracheids. Reason. The lumen of tracheids is narrow.
Deposition of fatty substance in the lining of arteries is termed as _______________
Deposition of fatty substance in the lining of arteries is termed as _______________
Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. In the above instrument, while measuring an internal diameter. ID is set of 321 mm with no zero error. It cap end is after 7^(th) division adn 17^(th) division of main scale coincides with the reference line, the ID is -
Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. During zero setting of the above instrument, the end of the cap is on left side of the zero of main scale (i.e. zero of main scale is not visible) and 41^(th) division of circular scale coincides with the reference line, the zero error is -
Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. During zero setting of the above instrument, the end of the cap is on left side of the zero of main scale (i.e. zero of main scale is not visible) and 41^(th) division of circular scale coincides with the reference line, the zero error is -
Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. During zero setting of the above instrument, the end of the cap is on left side of the zero of main scale (i.e. zero of main scale is not visible) and 41^(th) division of circular scale coincides with the reference line, the zero error is -
Water in a clean large cuboid aquarium forms a meniscus, as shown in the figure. The difference in height between the centre and the edge of the meniscus is h. Surface tension of water is S = 0.073 Nm^(-1) . Atmospheric pressure is P_0=10^5 N//m^2 . Angle of contact between the water and aquarium wall is zero. Answer the following 3 question above illustrated situation. For an aquarium with side walls of length l ,horizontal force on the volume of water enclosed by the dashed line and free surface, by one aquarium wall is
Recommended Questions
- The deposition of lipids on the wall lining the lumen of large and med...
Text Solution
|
- Hardening of the arteries due to deposition of cholesterol on arterial...
Text Solution
|
- Which coronary artery diseases is caused due to narrowing of the lumen...
Text Solution
|
- Assertion :- Xylem fibres have highly thickened walls and continous ce...
Text Solution
|
- In which disease arteries lumen become narrower due to the deposition ...
Text Solution
|
- The deposition of lipids on the wall lining the lumen of large and med...
Text Solution
|
- Assertion Arteries pump blood away from the heart at very low pressure...
Text Solution
|
- Which coronary artery disease is caused due to the narrowing of the lu...
Text Solution
|
- Deposition of fatty substance in the lining of arteries is termed as
Text Solution
|