One increasing the operating voltage in a x-ray tube by `1.5` times, the shortest wavelength decreases by `26 "pm"`. Find the original value of operating voltage.

A

`1*24 times 10^(4)V`

B

`15*9 times 10^(-2)V`

C

`3 times 10^(6)V`

D

`15*9 times 10^(3)V`

Text Solution

Verified by Experts

The correct Answer is:
D

`K.E.=(hc)/(lambda_(min)) rArr lambda_(min)=(hc)/(K.E.)` `26 times 10^(-2)=1.24 times 10^(4) times 1/(3V)`
`therefore V=(1.24 times 10^(4))/(3 times 26 times 10^(-2))=15.9 times 10^(3)V`
Promotional Banner

Topper's Solved these Questions

  • ATOMIC PHYSICS

    MTG-WBJEE|Exercise WBJEE WORKOUT (CATEGORY 2 : Single Option Correct Type )|15 Videos
  • ATOMIC PHYSICS

    MTG-WBJEE|Exercise WBJEE WORKOUT (CATEGORY 3 :One or More than One Option Correct Type )|10 Videos
  • ATOMS MOLECULES AND CHEMICAL ARITHEMETIC

    MTG-WBJEE|Exercise WB JEE PREVIOUS YEARS QUESTIONS CATEGORY 1: SINGLE OPTION CORRECT TYPE (1 MARK)|3 Videos

Similar Questions

Explore conceptually related problems

The short-wavelength limit shifts by 26 pm when the operating voltage in an X-ray tube is increased to 1.5 times the original value. What was the original value of the operating voltage?

The operating voltage in an -X-ray tube is increased to 3 times the original value of when the short wavelength limits shifs by 25 nm. Find the original value or the opreating voltage.

If the operating potential in an X-ray tube is increased by 1%, by what percentage does the cutoff wavelength decrease?

In the Coolidage tube experiment, if the applied voltage is increased to three times, the short wavelength limit of continuous X- ray spectrum shift by 20 pm. What is the intial voltage (in kV) applied to the tube?

The shortest wavelength produced in an X-ray tube operating at 0.5 million volt is

The distance between the cathode (filament) and the target in an X-ray tube is 1.5 m. If the cutoff wavelength is 30 pm, find the electric field between the cathode and the target.

What is the operating voltage of a medical x-ray machine that has a cut-off wavelength of 2.20xx10^(-11)m ?

An X-ray tube is operated at 20 kV. The cut off wavelength is

The operating potential in an x-ray tube is increased by 2%. The percentage change in the cut off wavelength is