Home
Class 12
PHYSICS
The potential difference applied to an X...

The potential difference applied to an X-ray tube is increased. As a result, in the emitted radiation,

A

the intensity increases

B

the minimum wavelength increases

C

the intensity remains unchanged

D

the minimum wavelength decreases.

Text Solution

Verified by Experts

The correct Answer is:
C, D

For X-ray tube,
`lambda_(m)(in overset(@)(A))=(12375)/V`
As accelerating voltage is increased, `lambda_(m)` will decrease.
Number of electrons bombarding the target, determine the intensity (or quantity) of emitted radiation. Accelerating voltage does not change the intensity of X-rays emitted.
Promotional Banner

Topper's Solved these Questions

  • ATOMIC PHYSICS

    MTG-WBJEE|Exercise WBJEE PREVIOUS YEARS QUESTIONS (CATEGORY 1 : Single Option Correct Type )|7 Videos
  • ATOMIC PHYSICS

    MTG-WBJEE|Exercise WBJEE PREVIOUS YEARS QUESTIONS (CATEGORY 3 : One or More than One Option Correct Type )|1 Videos
  • ATOMIC PHYSICS

    MTG-WBJEE|Exercise WBJEE WORKOUT (CATEGORY 2 : Single Option Correct Type )|15 Videos
  • ATOMS MOLECULES AND CHEMICAL ARITHEMETIC

    MTG-WBJEE|Exercise WB JEE PREVIOUS YEARS QUESTIONS CATEGORY 1: SINGLE OPTION CORRECT TYPE (1 MARK)|3 Videos

Similar Questions

Explore conceptually related problems

The potential different applied to an X-rays tube is increase .As a result , in the emitted radiation

The filament current in the electron gun of a coolidge tube is increased while the potential difference used to accelerate the electrons is decreased. As a result, in the emitted radiation

If the potential difference applied across a Collidage tube is increased,

If the potential difference applied across a Coolidge tube is increased , then

The stopping potential in a photoelectric experiment is linearly related to the inverse of the wavelength (1/lambda) of the light falling on the cathode. The potential difference applied across an X-ray tube is linearly related to the inverse of the cutoff wavelength (1/lambda) of the X-ray emitted. Show that the slopes of the lines in the two cases are equal and find its value.

If the potential difference applied to an X-ray tube is doubed while keeping the separation between the filament and the target as same, what will happen to the cutoff wavelength?

The potential difference applied to an X-ray tube is V The ratio of the de Broglie wavelength of electron to the minimum wavlength of X-ray is directrly proportional to

The potential difference applied to an X - ray tube is 5 kV and the current through it is 3.2 . Then the number of electrons striking the target per second is

The potential difference applied to an X-ray tube is 5 kV and the current through it is 3.2 mA. Then the number of electros striking the target par second is