A town situated 20 kW away from a power plant generating power at 440 V requires 600 KW of electric power at 200 V. The resistance of two wire lines carrying poweris `0.4 Omega` per km. The town gets power from the line through a 3000-220 V step down transformer at a substation in the town. Find line power losses in the form of heat. How much power must the plant supply assuming that there is negligilbe power loss due to leakage ?

Promotional Banner

Similar Questions

Explore conceptually related problems

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two line wires carrying power is 0.5 Omega per km. The town gets power from the lines through a 4000-220 V step down transformer at a substation in the town. Estimate the line power loss in the form of heat. (b) How much power must the plant supply. assuming there is negligible power loss due to leakage? (c) Characterize the step up transformer at the plant.

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two line wires carrying power is 0.5 Omega per km. The town gets power from the lines through a 4000-220 V step down transformer at a substation in the town. (a) Estimate the line power loss in the form of heat. (b) How much power must the plant supply. assuming there is negligible power loss due to leakage? (c) Characterize the step up transformer at the plant.

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two line wires carrying power is 0.5 Omega per km. The town gets power from the lines through a 4000-220 V step down transformer at a substation in the town. Estimate the line power loss in the form of heat. (b) How much power must the plant supply. assuming there is negligible power loss due to leakage? (c) Characterize the step up transformer at the plant.

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two wire line carrying power is 0.5 Omega per km. The town gets power from the line through a 4000-220 V step-down transformer at a sub-station in the town. (a) Estimate the line power loss in the form of heat. (b) How much power must the plant supply, assuming there is negligible power loss due to leakage? (c) Characterise the step up transformer at the plant.

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two wire line carrying power is 0.5 Omega per km. The town gets power from the line through a 4000-220 V step-down transformer at a sub-station in the town. (a) Estimate the line power loss in the form of heat. (b) How much power must the plant supply, assuming there is negligible power loss due to leakage? (c) Characterise the step up transformer at the plant.

A small town with a demand of 800 kW of electric power at 220 V is situated 15 km away from an electric plant generating power at 440 V. The resistance of the two wire line carrying power is 0.5 Omega per km. The town gets power from the line through a 4000-220 V step-down transformer at a sub-station in the town. a. Estimate the line power loss in the form of heat. b. How much power must the plant supply assuming there is negligible power less due to leakage? c. Characterise the step up transformer at the plant.