Home
Class 12
BIOLOGY
Is it true that if the dissolved oxygen ...

Is it true that if the dissolved oxygen level drops to zero, the water will become septic. Give an example which could lower the dissolved oxygen content of an aquatic body. 

Text Solution

Verified by Experts

Yes, the water become septic if the dissolved oxygen drops to zero. A very good example of it is organic pollution (biodegradable).
Promotional Banner

Topper's Solved these Questions

  • ENVIRONMENTAL ISSUES

    KUMAR PRAKASHAN|Exercise Section - E (Solution of NCERT Exemplar)(Long Answer Type Questions )|7 Videos
  • ENVIRONMENTAL ISSUES

    KUMAR PRAKASHAN|Exercise Section - F (Multiple Choice Question (MCQs))(MCQs FROM .DARPAN. BASED ON TEXTBOOK)|208 Videos
  • ENVIRONMENTAL ISSUES

    KUMAR PRAKASHAN|Exercise Section - E (Solution of NCERT Exemplar)(Very Short Answer Type Questions (VSQs))|15 Videos
  • ECOSYSTEM

    KUMAR PRAKASHAN|Exercise SECTION - F (MCQs ASKED IN COMPETTIVE EXAM)|84 Videos
  • EVOLUTION

    KUMAR PRAKASHAN|Exercise SECTION - F (Multiple Choice Questions)|198 Videos

Similar Questions

Explore conceptually related problems

In an experiment to estimate the size of a molecule of oleic acid 1 mL of oleic acid is dissolved in 19 ml of alcohol. Then I mL of this solution is diluted to 20 mL by adding alcohol. Now 1 drop of this diluted solution is placed on water in a shallow through. The solution spreads over the surface of water forming one molecule thick layer. Now lycopodium powder is sprinkled evenly over the film and its diameter is measured. Knowing the volume of the drop and area of the film we can calculate the thickness of the film which will give us the size of oleic acid molecule. Read the passage carefully and answer the following questions. (a) Why do we dissolve oleic acid in alcohol ? (b) What is the role of lycopodium powder ? (c) What would be the volume of oleic acid in each ml of solution prepared ? (d) How will you calculate the volume of n drops of this solution of oleic acid ? (e) What will be the volume of oleic acid in one drop of this solution ?

An electromagnetic wave can be represented by E = A sin (kx- omega t + phi) , where E is electric field associated with wave, According this equation, for any value of x, E remains sinusoidal for -oolt t lt oo . Obviously this corresponds to an idealised situation because radiation from ordinary sources consists of finite size wavetrains. In general, electric field remains sinusoidal only for times of order tau_(c) ' which is called coherence time. In simpler language it means that for times of order tau_(c)' a wave will have a definite phase. The finite value of coherence time could be due to many factors, for example if radiating atom undergoes collision with another atom then wave train undergoes an abrupt phase change or due to the fact that an atom responsible for emitting radiation has a finite life time in the energy level from which it drops to lower energy level, while radiating. Concept of coherence time can be easily understood using young's double slit experiment. Let interference patten is observed around point P at time t , due to superposition of waves emanting from S_(1) and S_(2) at times t =(r_(1))/(c) and (r_(2))/(c) respectively, where r_(1) and r_(2) are the distances S_(1) P & S_(2)P . Obviously if (r_(2)-r_(1))/(c) lt lt tau_(e),{"where" " "c = 3xx10^(8)m//s} then, wavetrain arriving at point P from S_(1) & S_(2) will have a definite phase relationship and an interference pattern of good contranst will be obtained. If coherence time is of order 10^(-10) second and screen is placed at a very large distance from slits in the given figure, then:-

An electromagnetic wave can be represented by E = A sin (kx- omega t + phi) , where E is electric field associated with wave, According this equation, for any value of x, E remains sinusoidal for -oolt t lt oo . Obviously this corresponds to an idealised situation because radiation from ordinary sources consists of finite size wavetrains. In general, electric field remains sinusoidal only for times of order tau_(c) ' which is called coherence time. In simpler language it means that for times of order tau_(c)' a wave will have a definite phase. The finite value of coherence time could be due to many factors, for example if radiating atom undergoes collision with another atom then wave train undergoes an abrupt phase change or due to the fact that an atom responsible for emitting radiation has a finite life time in the energy level from which it drops to lower energy level, while radiating. Concept of coherence time can be easily understood using young's double slit experiment. Let interference patten is observed around point P at time t , due to superposition of waves emanting from S_(1) and S_(2) at times t =(r_(1))/(c) and (r_(2))/(c) respectively, where r_(1) and r_(2) are the distances S_(1) P & S_(2)P . Obviously if (r_(2)-r_(1))/(c) lt lt tau_(e),{"where" " "c = 3xx10^(8)m//s} then, wavetrain arriving at point P from S_(1) & S_(2) will have a definite phase relationship and an interference pattern of good contranst will be obtained. If coherence time is of order 10^(-10) second and screen is placed at a very large distance from slits in the given figure, then:-