1 MW power is to be delivered from a power station to a town 10 km away. One uses a pair of Cu wires of radius 0.5 cm for this purpose. Calculate the fraction of ohmic losses to power transimitted if (i) power is transformer is used to boost the voltage to 11000 V, power transmitted, then a step down transformer is used to bring voltages to 220 V. `(rho_(Cu) = 1.7 xx 10^(-8) SI`unit)

A

`1.8%`

B

`1.5%`

C

`3.6%`

D

`7.2%`

Text Solution

Verified by Experts

The correct Answer is:
C

Given, `l=20 km = 20xx10^(3)m`
`r=0.5 cm =0.5xx10^(-2)m, rho = 1.7xx10^(-8)Omega m`
`R=(rho l)/(A)=(1.7xx10^(-8)xx20xx10^(3))/(3.14xx(0.5xx10^(-2))^(2))=4.3 Omega`
`P=10^(6)W, V=11000 V`
`I=(P)/(V)=(10^(6))/(11000)=(10^(3))/(11)A`
Power loss, `I^(2)R=((10^(3))/(11))^(2)xx4.3=3.6xx10^(4)W`
`(P_("LOST"))/(P_("TRANSMITTED"))xx100%=(3.6xx10^(4))/(10^(6))xx100=3.6%`
Promotional Banner

Topper's Solved these Questions

  • ALTERNATING CURRENT

    NCERT FINGERTIPS ENGLISH|Exercise NCERT|7 Videos
  • ALTERNATING CURRENT

    NCERT FINGERTIPS ENGLISH|Exercise ASSERTION & REASON|15 Videos
  • ALTERNATING CURRENT

    NCERT FINGERTIPS ENGLISH|Exercise Assertion And Reason|15 Videos
  • ATOMS

    NCERT FINGERTIPS ENGLISH|Exercise Assertion And Reason|15 Videos

Similar Questions

Explore conceptually related problems

Power alcohol is used in :

In transformer , power of secondary coil is :

Assertion : An ideal transformer does not vary the power. Reason : An transformer is used to step-up or step-down ac voltages.

What is the nature of current transmitted from the power station ?

The loss of power in a transformer can be reduced by :

In nuclear power station energy of uranium is used for producing-

State the principle of working of a transformer. Can a transformer be used to step up or step down a d.c. voltage? Justify your answer.

Fuel used in thermal power plants is :

A loss-free transformer having 100 turns in primary is used to transmit 10 KW of power . The input voltage is 200 V and power is transmitted at 5 KV. The current in the primary and secondary of the transformer are

In the transmission of power the voltage of power generated at the generating station is stepped up from 11 kV to 132 kV before it is transmitted. Why?