Home
Class 12
PHYSICS
Explain the construction and working of ...

Explain the construction and working of a transformer. Derive an expression for ratio of emfs in terms of number of turns in primary and secondary coil (march 14,16 july 17).

Promotional Banner

Topper's Solved these Questions

  • Electromagnetic Induction

    CHETANA PUBLICATION|Exercise EXERCISE|109 Videos
  • Dual Nature of Radiation and Matter

    CHETANA PUBLICATION|Exercise EXERCISE|89 Videos
  • Electrostatics

    CHETANA PUBLICATION|Exercise Exercise|73 Videos

Similar Questions

Explore conceptually related problems

The ratio of the turns in the primary and secondary coils of transformer is1: 9. The ratio of the current in the primary to secondary is

The primary of transformer has 5000 turns and works on 400V and 100 Walt. Find the number of turns in the secondary to step down voltage to 100V.

In a step up transformer, the input voltage is 300 V and the output voltage is 15 kV. Then the ratio of the number of turns in the primary to that in the secondary is

A step down transformer converts a voltage of 2200 V into 220V in the transmission line. Number of turns in primary coil is 5000. Efficiency of the transformer is 90% and its output power is 8 kW. Calculate the number of turns in the secondary coil.

The primary of a transformer has 40 turns and works on 100 volt and 100 watt.Find the number of turns in the secondary to step up voltage to 400 V. Also calculate the current in the secondary and primary.

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate the number of turns in secondary

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate current in the secondary.

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate the voltage across the secondary

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate the current in the primary

A step down transformer converts a voltage of 2200 V into 220V in the transmission line. Number of turns in primary coil is 5000. Efficiency of the transformer is 90% and its output power is 8 kW. Calculate the input power.

CHETANA PUBLICATION-Electromagnetic Induction-EXERCISE
  1. Explain the construction and working of a transformer. Derive an expre...

    Text Solution

    |

  2. A magnetic flux associated with a coil changes by 5xx10^-2 Wb in 25 se...

    Text Solution

    |

  3. The current in one coil increasesfrom0 to 500 mA in 0.1 ms. The induce...

    Text Solution

    |

  4. An emf of 100 mV is induced in a conductor of length 1.2m when it move...

    Text Solution

    |

  5. The current increases at the rate of 10A s^-1 in the coil of inductan...

    Text Solution

    |

  6. The current in a coil changes from zero to 5A in 0.2 seconds, due to w...

    Text Solution

    |

  7. The mutual inductance between the two coils is 2 xx 10^-2H.Due to the ...

    Text Solution

    |

  8. A step down transformer, connected to mains supply 240V is made to ope...

    Text Solution

    |

  9. The primary winding of a transformer has 300 turns and its secondary w...

    Text Solution

    |

  10. A coil of effective area 10m^2 is placed at right angles to a magnetic...

    Text Solution

    |

  11. The current increases at the rate of 10A s^-1 in the coil of inductan...

    Text Solution

    |

  12. A coil of effective area 4m^2 is placed at right angles to a magnetic ...

    Text Solution

    |

  13. A rectangular coil (0.5 m xx 0.4m) has a resistance of 5Omega . The co...

    Text Solution

    |

  14. A rectangular coil (0.5 m xx 0.4m) has a resistance of 5Omega . The co...

    Text Solution

    |

  15. A coil of area 0.75 m^2 and 1000 turns is kept perpendicular to a magn...

    Text Solution

    |

  16. Find the self-inductance of a circuit in which an e.m.f. of 10V is ind...

    Text Solution

    |

  17. The mutual inductance of a pair of coils is 0.75H. If the current in t...

    Text Solution

    |

  18. A step down transformer has 800 turns in the primary. The supply volta...

    Text Solution

    |

  19. A coil of effective area 2m^2 is placed at right angles to a magnetic ...

    Text Solution

    |

  20. The back e.m.f. induced in an inductive coil is 100 V when the current...

    Text Solution

    |

  21. The coefficient of mutual inductance between a pair of coils is 5mH. F...

    Text Solution

    |