Home
Class 12
PHYSICS
A step down transformer has 800 turns in...

A step down transformer has 800 turns in the primary. The supply voltage is 240 V. If the transformer is to be used to light a 6V lamp, what should be the number of turns in the secondary?

Promotional Banner

Topper's Solved these Questions

  • Electromagnetic Induction

    CHETANA PUBLICATION|Exercise EXERCISE|109 Videos
  • Dual Nature of Radiation and Matter

    CHETANA PUBLICATION|Exercise EXERCISE|89 Videos
  • Electrostatics

    CHETANA PUBLICATION|Exercise Exercise|73 Videos

Similar Questions

Explore conceptually related problems

A step down transformer converts a voltage of 2200 V into 220V in the transmission line. Number of turns in primary coil is 5000. Efficiency of the transformer is 90% and its output power is 8 kW. Calculate the number of turns in the secondary coil.

A transformer decreases the alternating supply voltage from 2200 V to 220 V. If the number of turns in the primary coil of the transformer is 2000, calculate the number of turns in secondary.

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate the number of turns in secondary

The primary of transformer has 5000 turns and works on 400V and 100 Walt. Find the number of turns in the secondary to step down voltage to 100V.

In a step up transformer, the input voltage is 300 V and the output voltage is 15 kV. Then the ratio of the number of turns in the primary to that in the secondary is

The primary of a transformer has 40 turns and works on 100 volt and 100 watt.Find the number of turns in the secondary to step up voltage to 400 V. Also calculate the current in the secondary and primary.

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate current in the secondary.

An ideal transformer has 100 turns in the primary and 250 turns in the secondary .The peak value of the ac is 28 V.The r.m.s .secondary voltage is nearest to

In a step up transformer , the transformation ratio is 100. The primary voltage is 200V and input power is 1000 watt.The number of turns in the primary is 100. Calculate the current in the primary

A transformer has 250 volts applied to the primary and gives 4.6V in the secondary. The secondary is connected to a load which draws a current of 5A. The current in the primary is

CHETANA PUBLICATION-Electromagnetic Induction-EXERCISE
  1. Find the self-inductance of a circuit in which an e.m.f. of 10V is ind...

    Text Solution

    |

  2. The mutual inductance of a pair of coils is 0.75H. If the current in t...

    Text Solution

    |

  3. A step down transformer has 800 turns in the primary. The supply volta...

    Text Solution

    |

  4. A coil of effective area 2m^2 is placed at right angles to a magnetic ...

    Text Solution

    |

  5. The back e.m.f. induced in an inductive coil is 100 V when the current...

    Text Solution

    |

  6. The coefficient of mutual inductance between a pair of coils is 5mH. F...

    Text Solution

    |

  7. The magnetic flux through a closed circuit is phi= 15t-t+5 Weber. If t...

    Text Solution

    |

  8. The magnetic flux through a spark coil of 1000 turn changes from 1.0 W...

    Text Solution

    |

  9. Magnetic flux in a closed circuit of resistance 20Omega varies with ti...

    Text Solution

    |

  10. A square coil having500 turnseach of side10cm is placed normal to the ...

    Text Solution

    |

  11. The current in one coil increases from 0 mA to 500 mA in 0.1 ms. The ...

    Text Solution

    |

  12. The current increases at the rate of 10A s^-1 in the coil of inductan...

    Text Solution

    |

  13. Calculate the inductance of three inductors connected as shown:

    Text Solution

    |

  14. Three inductors each of 6.0 H are connected as shown. Whatis theequiva...

    Text Solution

    |

  15. A circular coil of 100 turns with a crosssectional area (A) of 1m^2is...

    Text Solution

    |

  16. A conductor rod of length (l)is moving with velocity (v)in a direction...

    Text Solution

    |

  17. Two inductor coils with inductances 10 mH and 20 mH are connected in s...

    Text Solution

    |

  18. A current through a coil of self inductance 10 mH increases from 0 to ...

    Text Solution

    |

  19. What is a energy required to build up a current of 1 A in an inductor ...

    Text Solution

    |

  20. Lenz's law of consequence of the law of conservation of?

    Text Solution

    |