Home
Class 11
PHYSICS
To locate null point, deflection battery...

To locate null point, deflection battery key `K_(1)` is pressed before the galvanometer key `K_(2)`. Explain why?

Text Solution

AI Generated Solution

To locate the null point in an experiment involving a galvanometer, it is crucial to press the deflection battery key \( K_1 \) before the galvanometer key \( K_2 \). Here’s a step-by-step explanation of why this sequence is important: ### Step-by-Step Solution: 1. **Understanding the Circuit Setup**: - The circuit consists of a battery connected via key \( K_1 \) and a galvanometer connected via key \( K_2 \). The galvanometer is used to detect current flow. 2. **Pressing Key \( K_1 \)**: ...
Promotional Banner

Topper's Solved these Questions

  • EXPERIMENTS

    DC PANDEY ENGLISH|Exercise Exercise 3.1|2 Videos
  • EXPERIMENTS

    DC PANDEY ENGLISH|Exercise Exercise 3.2|2 Videos
  • ELECTROSTATICS

    DC PANDEY ENGLISH|Exercise Integer|17 Videos
  • FLUID MECHANICS

    DC PANDEY ENGLISH|Exercise Medical entranes gallery|49 Videos

Similar Questions

Explore conceptually related problems

To locate null point deflection battery key (K_1) ios pressed before the galvanometer (K_2) Explanation why?

Assertion To locate null defiection the battery key (K_(1)) is pressed first and then the galvanom eter key (K_(2)) Reason if first K_(2) is pressed and then as soon as K_(1) is pressed current suddenly try to increase so due to self induction a large stopping emf is generated in galvanometer which may damage the glavanometer .

In the given circuit, calculate the ratio of currents through the battery if (1) Key K_(1) is pressed, K_(2) open and then (2) Key K_(2) is pressed, key K_(1) is opened

The galvanometer deflection , when key K_(1) is closed but K_(2) is open equals theta_(0) (see figure ) On closing k_(2) also and adjusting R_(2) to 5Omega , the deflection in galvanometer becomes (theta_(0))/(5) the resistnce of the galvanometer is then , given by [Neglect the internal resistance of battery]:

The resistances P,Q,R and S in the bridge shown are adjusted such that the deflection in the galvanometer G is zero when both the keys K_(1) and K_(2) are inserted. The galvanometer will show a momentary deflection if

Two coils C_(1) and C_(2) are kept coaxially as shown the coil C_(1) is connected to a battery and the coil C_(2) is connected to a galvanometer. The deflection in galvanometer can be increased by

The circuit shown here is used to compare the e.m.f. of the two cells E_(2) (E)_(1) gt E_(2) . The null point is at C when the galvanometer is connected to E_(1) . When the galvanometer is connected to E_(2) , the null point will be

The circuit shown here is used to compare the e.m.f. of the two cells E_(2) (E)_(1) gt E_(2) . The null point is at C when the galvanometer is connected to E_(1) . When the galvanometer is connected to E_(2) , the null point will be

Two students ‘X’ and ‘Y’ perform an experiment on potentiometer separately using the circuit given: Keeping other parameters unchanged, how will the position of the null point be affected it (i) X’ increases the value of resistance R in the set-up by keeping the key K_1 closed and the key K_2 open? (ii) Y’ decreases the value of resistance S in the set-up, while the key K_2 remain open and the key K_1 closed? Justify.

As shown in the figure initially switch k1 is open and k2 is closed and deflection of galvanometer is x. Now both switch are closed then the deflection in galvanometer is x/5 (given R_H= 5Omega) . The resistance of galvanometer is