Home
Class 12
PHYSICS
Tha scale of a galvanometer is divided i...

Tha scale of a galvanometer is divided into `150` equal divisions.The galvanometer has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV . The galvanometer be designed to read (i) `6` A per division and (ii) `1 V` per division?

Text Solution

AI Generated Solution

To solve the problem step by step, we need to determine the necessary resistance for the galvanometer to read the specified current and voltage ranges. ### Given Data: - Total divisions on the galvanometer (N) = 150 - Current sensitivity (S_I) = 10 divisions/mA - Voltage sensitivity (S_V) = 2 divisions/mV ### Step 1: Calculate Full Scale Voltage (V_fs) ...
Promotional Banner

Topper's Solved these Questions

  • ELECTRICAL MEASURING INSTRUMENTS

    CENGAGE PHYSICS ENGLISH|Exercise Solved Examples|4 Videos
  • ELECTRICAL MEASURING INSTRUMENTS

    CENGAGE PHYSICS ENGLISH|Exercise Exercise 6.1|15 Videos
  • ELECTRIC POTENTIAL

    CENGAGE PHYSICS ENGLISH|Exercise DPP 3.5|15 Videos
  • ELECTROMAGNETIC INDUCTION

    CENGAGE PHYSICS ENGLISH|Exercise compression type|7 Videos

Similar Questions

Explore conceptually related problems

A galvanometer with a scale divided into 100 equal divisions has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV. What adoptions are required to read (i) 5A for full scale and (ii) 1 division per volt?

A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per millivolt. In order that each division reads 1 volt, the resistance in ohms needed to be connected in series with the coil will be -

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

The sensitivity of a galvanometer is 60 divisions/Amp. When a shunt is used, its sensitivity becomes 10 divisions/amp. If galvanometer is of resistance 20Omega , · the value of shunt used is :

1 cm of main scale of a vernier callipers is divided into 10 divisions. The least count of the callipers is 0.005 cm , then the vernier scale must have.

1 cm of main scale of a vernier callipers is divided into 10 divisions. The least count of the callipers is 0.005 cm , then the vernier scale must have.

1 cm on the main scale of a vernier calipers is divided into 10 equal parts. If 10 divisions of vernier coincide with 8 small divisions of main scale, then the least count of the caliper is.

1 cm on the main scale of a vernier callipers is divided into 10 equal parts. If 10 divisions of vernier coincide with 8 small divisions of main scale, then the least count of the calliper is.

A galvanometer with a coil of resistance 100 Omega and a scale having 100 divisions has a current sensitivity of 25 muA//"division." How will you convert it into an ammeter of range 0 to 5 A?