The current sensitivity of a moving coil galvanometer can be increased by

A

Increasing the magnetic field of the permeanent magnet

B

Increasing the area of the deflecting coil

C

Increasing the number of turns in the coil

D

All of these

Text Solution

AI Generated Solution

The correct Answer is:
To solve the question regarding how to increase the current sensitivity of a moving coil galvanometer, we can follow these steps: ### Step-by-Step Solution: 1. **Understanding Current Sensitivity**: - Current sensitivity (S) of a moving coil galvanometer is defined as the deflection produced per unit current flowing through the coil. It can be expressed mathematically as: \[ S = \frac{N \cdot A \cdot B}{k} \] where: - \(N\) = Number of turns in the coil - \(A\) = Area of the deflecting coil - \(B\) = Magnetic field strength - \(k\) = Torsional constant of the coil 2. **Identifying Factors Affecting Current Sensitivity**: - From the formula, we can see that current sensitivity is directly proportional to \(N\), \(A\), and \(B\). This means if any of these quantities increase, the current sensitivity will also increase. 3. **Analyzing Each Option**: - **Increasing the Magnetic Field (B)**: - If we increase the strength of the magnetic field in which the coil is placed, it will increase the current sensitivity. - **Increasing the Area of the Deflecting Coil (A)**: - Increasing the area of the coil will also lead to an increase in current sensitivity as it is directly proportional to the area. - **Increasing the Number of Turns in the Coil (N)**: - Increasing the number of turns in the coil will likewise increase the current sensitivity. 4. **Conclusion**: - Since all three options (increasing \(B\), \(A\), and \(N\)) lead to an increase in current sensitivity, the correct answer to the question is: - **All of these**. ### Final Answer: The current sensitivity of a moving coil galvanometer can be increased by increasing the magnetic field of the permanent magnet, increasing the area of the deflecting coil, and increasing the number of turns in the coil. Therefore, the correct answer is **all of these**.
Doubtnut Promotions Banner Mobile Dark
|

Topper's Solved these Questions

  • MOVING CHARGES AND MAGNETISM

    AAKASH INSTITUTE ENGLISH|Exercise Assignment (Section B) Objective Type Questions (One option is correct)|35 Videos
  • MOVING CHARGES AND MAGNETISM

    AAKASH INSTITUTE ENGLISH|Exercise Assignment Section C (Objective Type Questions (More than one option are correct)|14 Videos
  • MOVING CHARGES AND MAGNETISM

    AAKASH INSTITUTE ENGLISH|Exercise Try Yourself|27 Videos
  • MOVING CHARGE AND MAGNESIUM

    AAKASH INSTITUTE ENGLISH|Exercise SECTION D|16 Videos
  • NUCLEI

    AAKASH INSTITUTE ENGLISH|Exercise ASSIGNMENT (SECTION-D)|10 Videos

Similar Questions

Explore conceptually related problems

The current sensitivity of a moving coil galvanometer increases by 20% when its resistance is doubled calculate, by what factor does the voltage sensitivity change?

The current sensitivity of a moving coil galvanometer increases by 20% when its resistance is increased by a factor 2. Calculate by what factor does the voltage sensitivity change?

Current sensitivity of a moving coil galvanometer is independent of

The best method to increase the sensitivity of a moving coil galvanometer is to increase the

To increase the current sensitivity of a moving coil galvanometer by 50% its resistance is increased so that the new resistance becomes twice its initial resistance. By what factor does its voltage sensitivity change?

Statement -1 : The sensitvity of a moving coil galvanometer is increased by placing a suitable magnetic material as a core inside the coil. Statement - 2: Soft iron has a high magnetic permeability and cannot be easily magnetized or demagnetized.

Statement -1 : The sensitvity of a moving coil galvanometer is increased by placing a suitable magnetic material as a core inside the coil. Statement - 2: Soft iron has a high magnetic permeability and cannot be easily magnetized or demagnetized.

In an attempt to increases the current sensitivity of a moving coil galvanometer, it is found that its resistance becomes double while the current sensitivity increases by 10%. The voltage sensitivity of the galvanometer changes by

The ratio of voltage sensitivity (V_S) and current sensitivity (I_S) of a moving coil galvanometer is

In order to increase the sensitivity of a moving coil galvanometer, one should decrease