A high tension wire is at a high potential with respect to a wire which is well grounded called Earth wire. You must have seen such wires stretched parallel to roads. There is a high tension wire between two points A and B. 1 km apart. The distance between HT wire and earth wire is 1 m. The resisatnce of the HT (and also the earth wire) is `1 Omega//m`. This wire is at a potential of 11 KV at point A w.r.t. to earth wire. and its is carrying 1 A current which returns back to the generator by through the earth wire. This wire is quite a thick wire. There is a sign board at a pole over which this wire is stretched reading DANGER, 11 KV. You might thick what would happen if one touched this wire. Will one feel a shock or not. Well ! it depends on whether the current through our body exceeds a particular valuem which we may call CRITICAL CURRENT.
If the Critical Current for the bird is 0.1 A, find the maximum power at 11 KV can be transmitted at point A so that the bird may not get shocl. Assume that the distance between the feet is 10 cm.

A

111 KW

B

11 KW

C

101 KW

D

110011 KW

Text Solution

Verified by Experts

The correct Answer is:
A
Promotional Banner

Topper's Solved these Questions

  • DAILY PRACTICE PROBLEM

    RESONANCE ENGLISH|Exercise DPP No.47|20 Videos
  • DAILY PRACTICE PROBLEM

    RESONANCE ENGLISH|Exercise DPP No.48|9 Videos
  • DAILY PRACTICE PROBLEM

    RESONANCE ENGLISH|Exercise DPP No.45|20 Videos
  • CURRENT ELECTRICITY

    RESONANCE ENGLISH|Exercise High Level Problems (HIP)|19 Videos
  • ELECTRO MAGNETIC WAVES

    RESONANCE ENGLISH|Exercise Exercise 3|27 Videos

Similar Questions

Explore conceptually related problems

A high tension wire is at a high potential with respect to a wire which is well grounded called Earth wire. You must have seen such wires stretched parallel to roads. There is a high tension wire between two points A and B. 1 km apart. The distance between HT wire and earth wire is 1 m. The resisatnce of the HT (and also the earth wire) is 1 Omega//m . This wire is at a potential of 11 KV at point A w.r.t. to earth wire. and its is carrying 1 A current which returns back to the generator by through the earth wire. This wire is quite a thick wire. There is a sign board at a pole over which this wire is stretched reading DANGER, 11 KV. You might thick what would happen if one touched this wire. Will one feel a shock or not. Well ! it depends on whether the current through our body exceeds a particular valuem which we may call CRITICAL CURRENT. If the above question find the current through the bird.

A high tension wire is at a high potential with respect to a wire which is well grounded called Earth wire. You must have seen such wires stretched parallel to roads. There is a high tension wire between two points A and B. 1 km apart. The distance between HT wire and earth wire is 1 m. The resisatnce of the HT (and also the earth wire) is 1 Omega//m . This wire is at a potential of 11 KV at point A w.r.t. to earth wire. and its is carrying 1 A current which returns back to the generator by through the earth wire. This wire is quite a thick wire. There is a sign board at a pole over which this wire is stretched reading DANGER, 11 KV. You might thick what would happen if one touched this wire. Will one feel a shock or not. Well ! it depends on whether the current through our body exceeds a particular valuem which we may call CRITICAL CURRENT. Why is H.T wire thick wire. Select the most appropriate option

A high tension wire is at a high potential with respect to a wire which is well grounded called Earth wire. You must have seen such wires stretched parallel to roads. There is a high tension wire between two points A and B. 1 km apart. The distance between HT wire and earth wire is 1 m. The resisatnce of the HT (and also the earth wire) is 1 Omega//m . This wire is at a potential of 11 KV at point A w.r.t. to earth wire. and its is carrying 1 A current which returns back to the generator by through the earth wire. This wire is quite a thick wire. There is a sign board at a pole over which this wire is stretched reading DANGER, 11 KV. You might thick what would happen if one touched this wire. Will one feel a shock or not. Well ! it depends on whether the current through our body exceeds a particular valuem which we may call CRITICAL CURRENT. If the potential difference between H.T and earth wire is 11 kV at point A, find p.d between these wires at point B

A high tension wire is at a high potential with respect to a wire which is well grounded called Earth wire. You must have seen such wires stretched parallel to roads. There is a high tension wire between two points A and B. 1 km apart. The distance between HT wire and earth wire is 1 m. The resisatnce of the HT (and also the earth wire) is 1 Omega//m . This wire is at a potential of 11 KV at point A w.r.t. to earth wire. and its is carrying 1 A current which returns back to the generator by through the earth wire. This wire is quite a thick wire. There is a sign board at a pole over which this wire is stretched reading DANGER, 11 KV. You might thick what would happen if one touched this wire. Will one feel a shock or not. Well ! it depends on whether the current through our body exceeds a particular valuem which we may call CRITICAL CURRENT. Consider a bird having effective resistance 10 Omega between its feet sitting on this high tension wire. The distance between its feet is 10 cm. Find the potential difference between the feet of the bird is approximately,

Live and earth wire

Give two characteristics of a high tension wire.

What is the colour code for the insulation on the earth wire ?

What is the colour code for the insulation on the earth wire

What is the colour code for the insulation on the earth wire?

Identify the following wires used in a household circuit : The wire is also called as the phase wire.