Home
Class 12
PHYSICS
The overall efficiency of a transformer ...

The overall efficiency of a transformer is 90%. The transformer is rated for an output of 9000 watt. The primary voltage is 1000 vot. The ratio of turns in the primary to the secondary coil is 5: 1. The iron losses at full ioad are 700 watt. The primary coil has a resistance of 1 ohm
In the above, the current in the primary coil is:

A

9amp

B

10amp

C

1amp

D

4.5amp

Text Solution

AI Generated Solution

Doubtnut Promotions Banner Mobile Dark
|

Topper's Solved these Questions

  • ALTERNATING CURRENT

    RESONANCE ENGLISH|Exercise EXERCISE-12|1 Videos
  • ALTERNATING CURRENT

    RESONANCE ENGLISH|Exercise EXERCISE-13|1 Videos
  • ALTERNATING CURRENT

    RESONANCE ENGLISH|Exercise EXERCISE-10|1 Videos
  • ATOMIC PHYSICS

    RESONANCE ENGLISH|Exercise Advanved level problems|17 Videos

Similar Questions

Explore conceptually related problems

The overall efficiency of a transformer is 90%. The transformer is rated for an output of 9000 watt. The primary voltage is 1000 vot. The ratio of turns in the primary to the secondary coil is 5: 1. The iron losses at full ioad are 700 watt. The primary coil has a resistance of 1 ohm In the above, the current in the secondary coll is :

The overall efficiency of a transformer is 90%. The transformer is rated for an output of 9000 watt. The primary voltage is 1000 vot. The ratio of turns in the primary to the secondary coil is 5: 1. The iron losses at full ioad are 700 watt. The primary coil has a resistance of 1 ohm The voltage in secondary coil is:

Knowledge Check

  • The overall efficiency of a transformer is 90%.The transformer is rated for an output of 9000 watt.The primary voltage is 1000 volt.The ratio of turns in the primary to the secondary coil is 5:1.The iron losses at full load are 700 watt.The primary coil has a resistance of 1ohm. In the above, the copper loss in the primary coil is

    A
    400 W
    B
    200 W
    C
    100 W
    D
    300 W
  • Similar Questions

    Explore conceptually related problems

    A transformer is used to step up an alternating emf of 200V to 440V. If the primary coil has 1000 turns, calculate the number of turns in the secondary coil.

    The secondary coil of an ideal step down transformer is delivering 500 watt power at 12.5 A current. If the ratio of turns in the primary to the secondary is 5 : 1 then the current flowing in the primary coil will be:

    If the input voltage of a transformer is 2500 volts and output current is 80 ampere . The ratio of number of turns in the primary coil to that in secondary coil is 20 : 1 . If efficiency of transformer is 100 % , then the voltage in secondary coil as :

    A transformer of efficiency 90% has turns ratio 1 : 10. If the voltage across the primary is 220 V and current in the primary is 0.5 A, then the current in secondary is

    A transformer has 1500 turns in the primary coil and 1125 turns in the secondary coil. If a voltage of 200V is applied across the primary coil , then the voltage in the secondary coil is :

    A transformer consisiting of 300 turns in the primary and 150 turns in the secondary gives output power of 2.2 kw. If the current in the secondary coil is 10 A, then the input voltage and current in the primary coil are:

    A transformer consisting of 300 turns in the primary and 150 turns in the secondary gives output power of 2.2 kW.If the current in the secondary coil is 10 A, then the input voltage and current in the primary coil are :