Home
Class 12
PHYSICS
A voltmeter of resistance 100 Omega co...

A voltmeter of resistance `100 Omega` connected to the terminals of a cell reads 2 V. When the voltmeter is replaced by a resistance `1Omega` and an ammeter of `1Omega` , the ammeter reads 1 A. The EMF of the cell is __________ V.

Text Solution

AI Generated Solution

To solve the problem, we need to find the EMF (Electromotive Force) of the cell based on the information provided about the voltmeter and the ammeter setup. Let's break down the solution step by step. ### Step 1: Understand the Setup with the Voltmeter When the voltmeter (with resistance \( R_v = 100 \, \Omega \)) is connected across the cell, it reads \( V = 2 \, V \). The relationship between the EMF (\( E \)), the current (\( I \)), and the internal resistance (\( r \)) of the cell can be expressed as: \[ V = E - I \cdot r \] Here, the current \( I \) through the voltmeter can be calculated using Ohm's law: ...
Promotional Banner

Topper's Solved these Questions

  • DC CIRCUIT

    VMC MODULES ENGLISH|Exercise LEVEL-1 JEE MAIN ARCHIVE|93 Videos
  • DC CIRCUIT

    VMC MODULES ENGLISH|Exercise JEE ADVANCED ARCHIVE|68 Videos
  • DC CIRCUIT

    VMC MODULES ENGLISH|Exercise LEVEL-2 DAILY TUTORIAL SHEET-4|10 Videos
  • CURRENT ELECTRICITY

    VMC MODULES ENGLISH|Exercise IN-CHAPTER EXERCISE-F|10 Videos
  • DYNAMICS OF A PARTICLE

    VMC MODULES ENGLISH|Exercise JEE Advance (Archive) Level - II (SINGLE OPTION CORRECT TYPE )|31 Videos

Similar Questions

Explore conceptually related problems

A voltmeter of range 2 V and resistance 300 Omega cannot be converted into ammeter of range

Resistance of 100 Omega and 200 Omega are connected in series with 220 V mains. When a voltmeter of 1000 Omega resistance is connected in parallel to 100 Omega , then the reading of voltmeter is

A voltmeter with resistance 500 Omega is used to measure the emf of a cell of internal resistance 4 Omega . The percentage error in the reading of the voltmeter will be

A cell of emf 3.4 V and internal resistance 3 Omega is connected to an ammeter having resistance 2Omega and to an external resistance of 100Omega . When a voltmeter is connected across the 100 Omega resistance, the ammeter reading is 0.04 A . Find the voltage reading by the voltmeter and its resistance. Had the voltmeter been an ideal one what would have been its reading?

A cell of emf 3.4 V and internal resistance 3 Omega is connected to an ammeter having resistance 2Omega and to an external resistance of 100Omega . When a voltmeter is connected across the 100 Omega resistance, the ammeter reading is 0.04 A . Find the voltage reading by the voltmeter and its resistance. Had the voltmeter been an ideal one what would have been its reading?

The range of voltmeter of resistance 300 Omega is 5 V. The resistance to be connected to convert it into an ammeter of range 5 A is

A battery of emf 12V and internal resistance 2 Omega is connected two a 4 Omega resistor. Show that the a voltmeter when placed across cell and across the resistor in turn given the same reading

Write any two factors on which internal resistance of a cell depends . The reading on a high resistance voltmeter , when a cell is connected across it , is 2.0 V . When the terminals of the cell are also connected to a resistance of 3 Omega as shown in the circuit , the voltmeter reading drops to 1.5 V . Find the internal resistance of the cell.

Given that the resistance the voltmeter is 200 Omega. Find the voltmeter.s reading.

Five identical lamps each of resistance R = 1500 Omega are connected to 300 V as shown in figure . The reading of ideal ammeter A is