Home
Class 12
MATHS
In how many ways can 15 members of a cou...

In how many ways can 15 members of a council sit along a circular table, when the secretary is to sit on one side of the chairman and the deputy secretary on the other side?

A

`12!xx2`

B

`24`

C

`15!xx2`

D

30

Text Solution

Verified by Experts

The correct Answer is:
A
Promotional Banner

Similar Questions

Explore conceptually related problems

In how many ways can 5 boys and 3 girls sit in a row so that no two girls are together ?

If 11 members of a committee sit at a round table so that the president and secretary always sit together, then the number of arrangements, is

In how many ways 7 men and 7 women can be seated around a round table such that no two women can sit together

In how many ways can 15 identical blankets be distributed among six beggars such that everyone gets at least one blanket and tow particular beggars get equal blankets and another three particular beggars get equal blankets.

A tea party is arranged for 16 persons along two sides of a long table with 8 chairs on each side. Four persons wish to sit on one particular and two on the other side. In how many ways can they be seated?

Eighteen guests are to be seated, half on each side of a long table. Four particular guests desire to sit on one p[articular side and three others on other side of the table. The number of ways in which the seating arrangements can be made is (11!)/(5!6!)xx 9!xx 9!.

Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. During zero setting of the above instrument, the end of the cap is on left side of the zero of main scale (i.e. zero of main scale is not visible) and 41^(th) division of circular scale coincides with the reference line, the zero error is -

Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. In an internal micrometer, main scale division is of 0.5 mm and there are 50 divisions in circular scale. The least count of the instrument is-

Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. In the above instrument, while measuring an internal diameter. ID is set of 321 mm with no zero error. It cap end is after n^(th) division adn 17^(th) division of main scale coincides with the reference line, the ID is -

A boat is to be manned by eight men, of whom 2 can only row on bow side and 1 can only row on stroke side; in how many ways can the crew be arranged?