Home
Class 11
PHYSICS
Internal micrometer is a measuring intru...

Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line

This is to be multiplied by LC to get circular scale reading.
Least count = value of 1 circular scale division `= ("pitch")/("number of division on circular scale")`
Length of rod A is chosen to match the `ID(PQ)` to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of `ID` to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side.

In an internal micrometer, main scale division is of 0.5 mm and there are 50 divisions in circular scale. The least count of the instrument is-

A

0.005 mm

B

0.001 mm

C

0.05 mm

D

0.01 mm

Text Solution

Verified by Experts

The correct Answer is:
D

Least count `= (0.5)/(50) = 0.01 mm`
Promotional Banner

Topper's Solved these Questions

  • ERROR AND MEASUREMENT

    ALLEN |Exercise Part-2(Exercise-2)(A)|16 Videos
  • ERROR AND MEASUREMENT

    ALLEN |Exercise Part-2(Exercise-2)(B)|22 Videos
  • ERROR AND MEASUREMENT

    ALLEN |Exercise Part-2(Exercise-2)(B)|22 Videos
  • ELASTICITY, SURFACE TENSION AND FLUID MECHANICS

    ALLEN |Exercise Exercise 5 B (Integer Type Questions)|3 Videos
  • KINEMATICS

    ALLEN |Exercise EXERCISE-2|89 Videos

Similar Questions

Explore conceptually related problems

Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. In the above instrument, while measuring an internal diameter. ID is set of 321 mm with no zero error. It cap end is after n^(th) division adn 17^(th) division of main scale coincides with the reference line, the ID is -

Internal micrometer is a measuring intrument used to measure internal diameter (ID) of a large cylinder bore with high accuracy. Construction is shown in figure. There is one fixed rod B (to the right in figure) and one moved rod A (to the left in figure). It is based on the particle of advancement of a screw when it is rotated in a nut with internal threads. Main scale reading can be directly seen on the hub which is fixed with respect to rod B. When the cap is rotated rod A moves in or cut depending on direction of rotation. The circular scale reading is seen by checking which division of circular scale coincide with the references line This is to be multiplied by LC to get circular scale reading. Least count = value of 1 circular scale division = ("pitch")/("number of division on circular scale") Length of rod A is chosen to match the ID(PQ) to be measured. Zero error is checked by taking reading between standard blocks fixed at normal value of ID to be measured. Zero error is positive if cap end is one the right of the main scale and negative it is on the left side. During zero setting of the above instrument, the end of the cap is on left side of the zero of main scale (i.e. zero of main scale is not visible) and 41^(th) division of circular scale coincides with the reference line, the zero error is -

Explain method to measure internal resistance of cell by using potentiometer.

A student measured the diameter of a wire using a screw gauge with least count 0.001cm and listed the measurement. The correct measurement is

Acceleration-velocity graph of a moving particle is shown in figure. The particle is

The circular scale of a screw gauge has 50 divisions and pitch of 0.5 mm. Find the diameter of sphere. Main scale reading is 2 -

Micrometer is used to measure dimension of molecule of oleic acid by monomolecular laye method.

The circular scale of a micrometer has 200 divisions and pitch of 2 mm . Find the measured value of thickness of a thin sheet. .

A screw gauge gives the following reading when used to measure the diameter of a wire. Main scale reading =0mm , circular scale reading =52 divisions. Given that 1mm on main scale corresponds to 100 divisions of the circular scale. The diameter of the wire from the above data is

ALLEN -ERROR AND MEASUREMENT-Part-2(Exercise-1)
  1. In a vernier calliper, N divisions of vernier scale coincide with (N-1...

    Text Solution

    |

  2. A vernier callipers having 1 main scale division = 0.1 cm to have a le...

    Text Solution

    |

  3. In a vernier callipers, N divisions of the main scale coincide with N ...

    Text Solution

    |

  4. In a vernier callipers the main scale and the vernier scale are made u...

    Text Solution

    |

  5. Consider the MB shown in the diagram, let the resistance X have temper...

    Text Solution

    |

  6. For a post office box, the graph of galvanometer deflection versus (R ...

    Text Solution

    |

  7. Identify which of the following diagrams represent the internal constr...

    Text Solution

    |

  8. In a meter bridge set up, which of the following should be the propert...

    Text Solution

    |

  9. The relative error in resistivity of a material where resistance = 1...

    Text Solution

    |

  10. In the searle's experiment, after every step of loading, why should we...

    Text Solution

    |

  11. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  12. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  13. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  14. In a given slide callipers 10 division of its vernier coincides with i...

    Text Solution

    |

  15. Consider a home made vernier scale as shown in the figure. In this dia...

    Text Solution

    |

  16. The pitch of a screw gauge is 1 mm and there are 50 divisions on its c...

    Text Solution

    |

  17. A short circuit occurs in a telephone cable having a resistance of 0.4...

    Text Solution

    |

  18. A glass prism of angle A = 60^(@) gives minimum angle of deviation the...

    Text Solution

    |

  19. In a given optical bench, a needle of length 10 cm is used to estimate...

    Text Solution

    |

  20. Consider S = X cos (theta) for X = (2.0 pm 0.2) cm, theta = 53 pm 2^(@...

    Text Solution

    |