A step-up transformer operates on a 220-...

A step-up transformer operates on a 220-V AC line and supplies a load current of 6 A. The ratio of the primary to secondary turns is 1:12. Find the current in the primary, voltage in the secondary, and output power, given that the efficiency of the transformer is 70%.

Text Solution

AI Generated Solution

To solve the problem step-by-step, we will follow these calculations: ### Step 1: Identify the given values - Primary voltage (\( V_p \)) = 220 V - Secondary current (\( I_s \)) = 6 A - Turns ratio (\( \frac{N_p}{N_s} \)) = 1:12 - Efficiency (\( \eta \)) = 70% = 0.70 ...
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    CENGAGE PHYSICS|Exercise MANDATORY EXERCISE (EXERCISE SET I)|5 Videos
  • ELECTROMAGNETIC INDUCTION

    CENGAGE PHYSICS|Exercise MANDATORY EXERCISE (EXERCISE SET II)|21 Videos
  • CURRENT ELECTRICITY

    CENGAGE PHYSICS|Exercise OLYMPIAD AND NTSE LEVEL EXERCISES|10 Videos
  • ELECTROMAGNETIC SPECTRUM AND RADIATIONS

    CENGAGE PHYSICS|Exercise Olympiad And NTSE Level Exercises|10 Videos

Similar Questions

Explore conceptually related problems

A step up transformer operates on a 230 V line and a load current of 2 ampere. The ratio of the primary and secondary windings is 1 : 25 . What is the current in the primary?

A step-up transfomer operates on a 220 volt line and supplies to load, a current of 2A. The ratio of primary and secondary winding is 1 : 25. Calculate secondary voltage, primary current and power output, if efficiency is 80%

A step - up transformer operates on 220V line and supplies 22A .The ratio of primary and secondary winding is 11:50. The output voltage in the secondary is

A slep-up transformer operates on 220 V line and supplies 2.2 A. The ratio of primary and secondary winding is 11 : 50, The output voltage in the secondary is

A transformer is used to reduce the main supply of 220V to 22V. If the currents in the primary and secondary are 2A and 15 A respectively, then the efficiency of the transformer is

A step-up transformer works on 220 V and gives 2 A to an external resistor. The turn ratio between the primary and secondary coils is 2 : 25. Assuming 100% efficiency, find the secondary voltage, primary current and power delivered respectively

The ratio of primary voltage to secondary voltage in a transformer is 'n' . The ratio of the primary current to secondary current in the transformer is