Home
Class 11
PHYSICS
A vernier callipers having 1 mai scale d...

A vernier callipers having 1 mai scale divison `=0.1cm` is designed to have a least count of `0.02cm`. If `n` be the number of divisions on vernier scale and `m` be the length of vernier scale, then

A

n = 10,m = 0.5 cm

B

n =9,m = 0.4 cm

C

n = 10,m = 0.8 cm

D

n = 10,m = 0.2 cm

Text Solution

Verified by Experts

The correct Answer is:
C

`becauseL.C=1MSD-1VSD`
`:. 0.02=0.1-(m)/(n)rArr (m)/(n)=0.08`
Promotional Banner

Topper's Solved these Questions

  • ERROR AND MEASUREMENT

    ALLEN|Exercise Part-2(Exercise-2)(A)|16 Videos
  • ERROR AND MEASUREMENT

    ALLEN|Exercise Part-2(Exercise-2)(B)|22 Videos
  • ERROR AND MEASUREMENT

    ALLEN|Exercise Part-2(Exercise-2)(B)|22 Videos
  • ELASTICITY, SURFACE TENSION AND FLUID MECHANICS

    ALLEN|Exercise Exercise 5 B (Integer Type Questions)|3 Videos
  • KINEMATICS

    ALLEN|Exercise EXERCISE-2|89 Videos

Similar Questions

Explore conceptually related problems

A vernier callipers having 1 main scale division = 0.1 cm to have a least count of 0.02 cm .If n be the number of divisions on vernier scale and m be the length of vernier scale, then.

A vernier calipers having 1 main scale division = 0.1 cm to have a least count of 0.02 cm .If n be the number of divisions on vernier scale and m be the length of vernier scale, then.

In a vernier callipers, one main scale division is x cm and n divisions of the vernier scale coincide with (n-1) divisions of the main scale. The least count (in cm) of the callipers is :-

Least count of a vernier callipers is 0.01 cm When the two jaws of the instrument touch each other the 5th division of the vernier scale coincide with a main scale division and the zero of the vernier scale lies to the left of the zero of the main scale. Furthermore while measuring the diameter of a sphere, the zero markof the vernier scale lies between 2.4 cm and 2.5 cm and the 6th vernier division coincides with a main scale division. Calculate the diameter of the sphere.

The least count of a veriner callipers is (1)/(100)cm . The value of one division on the main scale is 1mm. The, the number of divisions on the main scale that coincide with N divisions of the vernier is

In a vernier calipers, 1 cm of the main scale is divided into 20 equal parts. 19 divisions of the main scale coincide with 20 divisions on the vernier scale . Find the least count of the instrument.

The edge of a cube is measured using a vernier callipers. [ 9 divisions of the main scale is equal to 10 divisions of the vernier scale and 1 main scale dividsion is 1 mm ]. The main scale division reading is 10 and 1st division of vernier scale was found to be coinciding with the main scale. The mass of the cube is 2.736 g . Calculate the density in g//cm^3 upto correct significant figures.

A spectrometer gives the following reading when used to measure the angle of a prism. Main scale reading : 58.5 degree Vernier scale reading : 09 divisions Given that 1 division on main scale correspods to 0.5 degree. Total divisions on the vernier scale is 30 and match with 29 divisions of the main scale. the angle of the prism from the above data:

A vernier callipers has its main scale graduated in mm and 10 divisions on its vernier scale are equal in length to 9 mm. When the two jaws are in contact, the zero of vernier scale is ahead of zero of main scale and 3rd division of vernier scale coincides with a main scale division. Find the least count .

The main scale of a vernier callipers is calibrated in mm and 19 divisions of main scale are equal in length to 20 divisions of vernier scale. In measuring the diameter of a cylinder by this instrument, the main scale reads 35 divisions and the 4th division of vernier scale coincides with a main scale division. Find least count .

ALLEN-ERROR AND MEASUREMENT-Part-2(Exercise-1)
  1. What is the reading of micrometer screw gauge shown in the figure?

    Text Solution

    |

  2. In a vernier callipers N divisions of vernier scale coincide with N-1 ...

    Text Solution

    |

  3. A vernier callipers having 1 mai scale divison =0.1cm is designed to h...

    Text Solution

    |

  4. In a vernier callipers, N divisions of the main scale coincide with N+...

    Text Solution

    |

  5. In a vernier callipers the main scale and the vernier scale are made u...

    Text Solution

    |

  6. Consider the MB shown in the diagram, let the resistance X have temper...

    Text Solution

    |

  7. For a post office box, the graph of galvanometer deflection versus (R ...

    Text Solution

    |

  8. Identify which of the following diagrams represent the internal constr...

    Text Solution

    |

  9. In a meter bridge set up, which of the following should be the propert...

    Text Solution

    |

  10. The relative error in resistivity of a material where resistance = 1...

    Text Solution

    |

  11. In te Searle's experiment, after every step of loading, why should we ...

    Text Solution

    |

  12. In an internal micrometer, main scale division is of 0.5 mm and there ...

    Text Solution

    |

  13. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  14. Internal micrometer is a measuring intrument used to measure internal ...

    Text Solution

    |

  15. In a given slide callipers 10 division of its vernier coincides with i...

    Text Solution

    |

  16. Consider a home made vernier scale as shown in the figure. In this dia...

    Text Solution

    |

  17. The pitch of a screw gauge is 1 mm and there are 50 divisions on its c...

    Text Solution

    |

  18. A short circuit occurs in a telephone cable having a resistance of 0.4...

    Text Solution

    |

  19. A glass prism of angle A = 60^(@) gives minimum angle of deviation the...

    Text Solution

    |

  20. In a given optical bench, a needle of length 10 cm is used to estimate...

    Text Solution

    |