Home
Class 12
PHYSICS
E.M.F. of a thermocouple is 25 uV//.^(@...

E.M.F. of a thermocouple is 25 `uV//.^(@)C` A galvanometer whose resistance is 40omega, reads, `10^(-1)A` curren then minimum temperature which is determined by if will be

A

`8^(@)C`

B

`12^(@)C`

C

`16^(@)C`

D

`20^(@)C`

Text Solution

AI Generated Solution

Promotional Banner

Similar Questions

Explore conceptually related problems

A platinum resistance thermometer reads 0^@ C when its resistance is 80 Omega and 100^@ C when its resistance is 90 Omega . Find the temperature at which the resistance is 86 Omega .

The resistance of a wire at 20^(@)C is 20Omega and at 500^(@)C is 60Omega . At which temperature its resistance will be 25Omega ?

In the primary circuit of a potentiometer, a cell of E.M.F 1 V and a rheostat of 15 Omega are connected in series. If the resistance of the potentiometer wire is 10 Omega the minimum voltage at the ends of the wire (in V) will be

The resistance of the four arms A, B, C and D of a wheatstone bridge as shown in the figure are 10 Omega , 20 Omega , 30 Omega and 60 Omega respectively . The emf and internal resistance of the cell are 15 V and 2.5 Omega respectively . If the galvanometer resistance is 80 Omega then the net current drawn from the cell will be

A silver wire has a resistance of 2.1 Omega at 27.5^@C , and a resistance of 2.7 Omega at 100^@C , Determine the temperature coefficient of resistivity of silver.

The cold junction of a thermocouple is at 0^(@)C . The thermo e.m.f. epsilon , in volts, generated in this thermocouple varies with temperature t^(@)C of the hot junction as epsilon=6+4t-(t^(2))/(32) . The neutral temperature of the thermocouple

A thermocouple of negligible resistance produces an emf fo 40 mu V//^(@)C in the linear range of temperature. A galvanometer of resistance 10 Omega whose sensitivity is 1 mu A//div is employed with the thermocouple. The smallest value of temperature difference that can be detected by the system will

The smallest temperature difference that can be measured with a combination of a thermocouple of thermo e.m.f. 30mu V per degree and a galvanometer of 50 ohm resistance, capable of measuring a minimum current of 3xx10^(-7) amp is

If the galvanometer current is 10 mA, resistance of the galvanometer is 40 Omega and shunt of 2 Omega is connected to the galvanometer, the maximum current which can be measured by this ammeter is

A cell whose e.m.f. is 2V and internal resistance is 0.1Omega is connected with a resistance of 3.9Omega the voltage across the cell terminal will be