Home
Class 12
PHYSICS
A step-up transformer operates on a 200 ...

A step-up transformer operates on a 200 volt line and supplies a load of 2 ampere. The ratio of primary and secondary windings is 1:5. Determine the secondary voltge, primary current and power output. Assume efficiency to be 100%.

Promotional Banner

Topper's Solved these Questions

  • ALTERNATING CURRENTS

    MODERN PUBLICATION|Exercise EXERCISE|201 Videos
  • CAPACITOR

    MODERN PUBLICATION|Exercise EXAMPLE|262 Videos

Similar Questions

Explore conceptually related problems

A step up transformer is used on a 120 volt line to provide a potential difference of 2,400 volt at 2 ampere current . If primary has 1,000 turns, find the number of turns in secondary and current in the primary coil.

A step-down transformer is used at 220 volt line to provided a current of 0.5 ampere to a 15 watt bulb. If the secondary has 20 turns, find the current and number of turns in the primary coil.

Ratio of number of turns in primary and secondary coil of 440V-22000V step up transformer is

Calculate the current drawn by the primary windlings of a step-down transformer, whose primary and secondary voltages are 220V and 22V rspectively. A load resistance of 22 ohm is connected to its secondary windings and it operates at an efficiency of 75%.

A step-down transformer is used to reduce 220V supply to 11V. The primary draws 5 A of current, while th secondary 90 A. The efficiency of the transformer is

MODERN PUBLICATION-ALTERNATING CURRENTS-EXERCISE
  1. A step-up transformer operates on a 200 volt line and supplies a load ...

    Text Solution

    |

  2. A lamp is connected in series with a capacitor to a high frequency a.c...

    Text Solution

    |

  3. An air core coil and an electric bulb are connected in series across a...

    Text Solution

    |

  4. Answer the following questions: A choke coil in series with a lamp is ...

    Text Solution

    |

  5. A lamp is connected in series with a capacitor. What will happen if d....

    Text Solution

    |

  6. Explain : voltages across L and C in series are 180^(@) out of phase, ...

    Text Solution

    |

  7. The total impedance of a circuit decreases, when a capacitor is added ...

    Text Solution

    |

  8. When an a.. Circuit with a series combination of inductance, capacitan...

    Text Solution

    |

  9. When a capacitor is connected in series LR circuit the alternating cur...

    Text Solution

    |

  10. An alternating voltage of frequency f is applied across LCR circuit. L...

    Text Solution

    |

  11. An alternating voltage of frequency f is applied across LCR circuit. L...

    Text Solution

    |

  12. Give applications of resonance in series LCR circuit.

    Text Solution

    |

  13. An capacitor C, a variable resistor R and a bulb B are connected in se...

    Text Solution

    |

  14. An capacitor C, a variable resistor R and a bulb B are connected in se...

    Text Solution

    |

  15. A capacitor with capacitance C and a coil with active resistance R and...

    Text Solution

    |

  16. An inductor L of inductance X(L) is connected in series with a bulb B ...

    Text Solution

    |

  17. An inductor L of inductance X(L) is connected in series with a bulb B ...

    Text Solution

    |

  18. As shown in figure an electric lamp having coil of negligible inductan...

    Text Solution

    |

  19. As shown in figure an electric lamp having coil of negligible inductan...

    Text Solution

    |

  20. In the circuit shown below R represents an electric bulb. If the frequ...

    Text Solution

    |

  21. Show in the figure, two electric circuits A and B. Calculate the ratio...

    Text Solution

    |