Home
Class 12
PHYSICS
Tha scale of a galvanometer is divided i...

Tha scale of a galvanometer is divided into `150` equal divisions.The galvanometer has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV . The galvanometer be designed to read (i) `6` A per division and (ii) `1 V` per division?

A

`40 mu Omega` is connected in parallel, `1000 Omega` is connected in series

B

`20 mu Omega` is connected in parallel, `9995 Omega` is connected in series

C

`8.3 mu Omega` is connected in parallel, `9995 Omega` is connected in series

D

`8.3 xx 10^(-5) Omega` is connected in parallel, `9995 Omega` is connected in series

Text Solution

Verified by Experts

The correct Answer is:
D
Doubtnut Promotions Banner Mobile Dark
|

Topper's Solved these Questions

  • CURRENT ELECTRICITY

    AAKASH SERIES|Exercise LECTURE SHEET (EXERCISE-V LEVEL-II (ADVANCED) (Straight Objective Type Questions))|5 Videos
  • CURRENT ELECTRICITY

    AAKASH SERIES|Exercise LECTURE SHEET (EXERCISE-VI LEVEL - I (MAIN) (Straight Objective Type Questions))|9 Videos
  • CURRENT ELECTRICITY

    AAKASH SERIES|Exercise LECTURE SHEET (EXERCISE-IV LEVEL- II (ADVANCED) (Integer Type Questions))|4 Videos
  • CURRENT ELECTRICITY

    AAKASH SERIES|Exercise PROBLEMS (LEVEL-II)|27 Videos
  • DUAL NATURE OF RADIATION AND MATTER

    AAKASH SERIES|Exercise PRACTICE EXERCISEX|42 Videos

Similar Questions

Explore conceptually related problems

A galvanometer with a scale divided into 100 equal divisions has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV. What adoptions are required to read (i) 5A for full scale and (ii) 1 division per volt?

A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per millivolt. In order that each division reads 1 volt, the resistance in ohms needed to be connected in series with the coil will be -

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

The sensitivity of a galvanometer is 60 divisions/Amp. When a shunt is used, its sensitivity becomes 10 divisions/amp. If galvanometer is of resistance 20Omega , · the value of shunt used is :

1 cm of main scale of a vernier callipers is divided into 10 divisions. The least count of the callipers is 0.005 cm , then the vernier scale must have.

1 cm of main scale of a vernier callipers is divided into 10 divisions. The least count of the callipers is 0.005 cm , then the vernier scale must have.

1 cm on the main scale of a vernier calipers is divided into 10 equal parts. If 10 divisions of vernier coincide with 8 small divisions of main scale, then the least count of the caliper is.

1 cm on the main scale of a vernier callipers is divided into 10 equal parts. If 10 divisions of vernier coincide with 8 small divisions of main scale, then the least count of the calliper is.

A galvanometer with a coil of resistance 100 Omega and a scale having 100 divisions has a current sensitivity of 25 muA//"division." How will you convert it into an ammeter of range 0 to 5 A?