Home
Class 12
PHYSICS
A moving coil galvanometer has 150 equal...

A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10 divisions per milliampere and vlotage sensitivity is 2 divisions per millivolt. In order that each division reads 1 V the resistance in ohm needed to be connected in series with the coil will be

A

99995

B

9995

C

`10^3`

D

`10^5`

Text Solution

Verified by Experts

The correct Answer is:
B
Promotional Banner

Topper's Solved these Questions

  • APPENDICES ( REVISION EXERCISE )

    AAKASH SERIES|Exercise REVISION EXERCISE (MAGNETISM AND MATTER )|52 Videos
  • APPENDICES ( REVISION EXERCISE )

    AAKASH SERIES|Exercise REVISION EXERCISE (CUTTENT ELECTRICITY )|108 Videos
  • ALTERNATING CURRENT

    AAKASH SERIES|Exercise EXERCISE - III|24 Videos
  • APPENDICES (REVISION EXERCISE)

    AAKASH SERIES|Exercise LAW OF MOTION|128 Videos

Similar Questions

Explore conceptually related problems

A moving coil galvanometer has 150 equal divisions. Its current sensitivity is 10-divisions per milliampere and voltage sensitivity is 2 divisions per millivolt. In order that each division reads 1 volt, the resistance in ohms needed to be connected in series with the coil will be -

A galvanometer with a scale divided into 100 equal divisions has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV. What adoptions are required to read (i) 5A for full scale and (ii) 1 division per volt?

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

A galvanometer having 30 divisions has current sensitivity of 20 mu A//"division" . Find the maximum current it can measure.

Tha scale of a galvanometer is divided into 150 equal divisions.The galvanometer has a current sensitivity of 10 divisions per mA and a voltage sensitivity of 2 divisions per mV . The galvanometer be designed to read (i) 6 A per division and (ii) 1 V per division?

Current senstivity of moving coil galvanometer is 5 "div"//mA and its voltage senstivity (angular deflection per unit voltage applied) is 20 "div"//V . The resistance of the galvanometer is

A galvanometer has 30 divisions and a sensitivity 16 mu A //"div" . It can be converted into a voltmeter to read 3 V by connecting

The sensitivity of a galvanometer is 60 divisions/Amp. When a shunt is used, its sensitivity becomes 10 divisions/amp. If galvanometer is of resistance 20Omega , · the value of shunt used is :

A galvanometer of resistance 40Omega and current passing through it is 100muA per divison. The full scale has 50 divisions. If it is converted into an ammeter of range 2A by using a shunt, then the resistance of ammeter is

Consider a Vernier callipers in which each 1cm on the main scale is divided into 8 equal divisions and a screw gauge with 100 divisions in its circular scale. In the Vernier callipers, 5 divisions of the Vernier scale coincide with 4 divisions on the scale and in the screw gauge, one complete rotation of the circular scale moves it by two divisions on the linear scale. Then :

AAKASH SERIES-APPENDICES ( REVISION EXERCISE )-REVISION EXERCISE (MOVING CHANGES & MEGNETISM)
  1. Three long straight and parallel wires carrying currents are arranged ...

    Text Solution

    |

  2. Two parallel horizontal conductors are suspended by two light vertical...

    Text Solution

    |

  3. Along wire carrying a current of 40A as shown in figure. The rectangul...

    Text Solution

    |

  4. Two long parallel wires are at a distance 2d apart. They carry steady ...

    Text Solution

    |

  5. A conducting ring of mass 2kg, radius 0.5m carries a current of 4A. I...

    Text Solution

    |

  6. A wire fo length l is bent in the from of a circular coil of some tur...

    Text Solution

    |

  7. A rectangular coil 6 cm long and 2 cm wide is placed in a magnetic fie...

    Text Solution

    |

  8. A circular coil of 20 turns and radius 10 cm is placed in uniform magn...

    Text Solution

    |

  9. A moving coil galvanometer 'A' has 200 turns and a resistance of 100Om...

    Text Solution

    |

  10. A tangent galvanometer has 66 turns and the diameter of its coil is 22...

    Text Solution

    |

  11. A galvanometer has a resistance of 3663Omega. A shunt S is connected a...

    Text Solution

    |

  12. A galvanometer having a resistance of 50Omega, gives a full scale defl...

    Text Solution

    |

  13. A galvanometer has a resistance G and current I(a) flowing in it. Prod...

    Text Solution

    |

  14. The deflection of a galvanometer falls to 1//10^(th) when a resistanc...

    Text Solution

    |

  15. A moving coil galvanometer has 150 equal divisions. Its current sensit...

    Text Solution

    |

  16. A straight rod of mass m and lenth L is suspended from the identical s...

    Text Solution

    |

  17. A rigid circular loop of radius r and mass m lies in the xy-plane on a...

    Text Solution

    |

  18. In the circuit diagrams (A,B,C and D) shown below, R is a high resista...

    Text Solution

    |

  19. To find the resistance of a galvanometer by the half deflection method...

    Text Solution

    |

  20. Deflection of galvanometer in the circuit is 71 divisions. A shunt of...

    Text Solution

    |