Home
Class 11
PHYSICS
The pitch of a screw gauge is 1 mm and t...

The pitch of a screw gauge is 1 mm and there are `100 "divisions"` on circular scale. When faces `A` and `B` are just touching each without putting anything between the studs 32nd divisions of the circular scale (below its Zero) coincides with the reference line. When a glass plate is placed between the studs, the linear scale reads 4 divisions and the circular reads 16 divisions. Find the thickness of the glass plate. Zero of linnear scale is not hidden from circular scale when A and B touches each other.

Promotional Banner

Similar Questions

Explore conceptually related problems

The pitch of a screw gauge is 1 mm and there are 100 divisions on circular scale. When the two studs of the screw gauge are touching each other, the 32^(nd) division of the circulasr scale coincides with the reference line / base line / index line on the pitch scale. When a glass plate is placed in between the studs firmly, the pitch scale reads 4 divisions and the circular scale reads 16 divisions The thickness of glass plate is

The pitch of a screw gauge is 1 mm and there are 100 divisions on circular scale. When the two studs of the screw gauge are touching each other, the 32^(nd) division of the circulasr scale coincides with the reference line / base line / index line on the pitch scale. When a glass plate is placed in between the studs firmly, the pitch scale reads 4 divisions and the circular scale reads 16 divisions The thickness of glass plate is

The pitch of a screw gauge is 1 mm and there are 100 divisions on circular scale. When the two studs of the screw gauge are touching each other, the 32^(nd) division of the circulasr scale coincides with the reference line / base line / index line on the pitch scale. When a glass plate is placed in between the studs firmly, the pitch scale reads 4 divisions and the circular scale reads 16 divisions Least count of the apparatus is

The pitch of a screw gauge is 1 mm and there are 100 divisions on circular scale. When the two studs of the screw gauge are touching each other, the 32^(nd) division of the circulasr scale coincides with the reference line / base line / index line on the pitch scale. When a glass plate is placed in between the studs firmly, the pitch scale reads 4 divisions and the circular scale reads 16 divisions Least count of the apparatus is

The pitch of a screw gauge is 1 mm and there are 50 divisions on its cap. When nothing is put in between the studs, 44th division of the circular scale coincides with the refersence line zero of the main scale is not visible. When a glass plate is placed between the studs, the main scale reads three divisions and the circular scale reads 26 divisions. The thickness of the plate is (360+a)xx10^(-2) mm. Find 'a'.

The pitch of a screw gauge is 1 mm and there are 100 divisions on circular scale. When the two studs of the screw gauge are touching each other, the 32^(nd) division of the circulasr scale coincides with the reference line / base line / index line on the pitch scale. When a glass plate is placed in between the studs firmly, the pitch scale reads 4 divisions and the circular scale reads 16 divisions Zero correction of the instrument is

The pitch of a screw gauge is 1 mm and there are 100 divisions on circular scale. When the two studs of the screw gauge are touching each other, the 32^(nd) division of the circulasr scale coincides with the reference line / base line / index line on the pitch scale. When a glass plate is placed in between the studs firmly, the pitch scale reads 4 divisions and the circular scale reads 16 divisions Zero correction of the instrument is

The pitch of a screw gauge is 1 mm and there are 50 divisions on its cap. When nothing is put in between the studs, 44th divisions of the circular scale coincides with the reference line and the line and the zero of the main scale is not visible or zero of circular scale is lying above the reference line. When a glass plate is placed between the studs, the main scale reads three divisions and the circular scale reads 26 divisions. Calculate the thickness of the plate.

The pitch of a screw gauge is 1 mm and there are 50 divisions on its cap. When nothing is put in between the studs, 44th divisions of the circular scale coincides with the reference line and the line and the zero of the main scale is not visible or zero of circular scale is lying above the reference line. When a glass plate is placed between the studs, the main scale reads three divisions and the circular scale reads 26 divisions. Calculate the thickness of the plate.

The pitch of a screw gauge is 1 mm and there are 100 division on its circular scale. When nothing is put in between its jaws, the zero of the circular scale lies 4 divisions below the reference line. When a steel wire is placed between the jaws, two main scale divisions are clearly visible and 67 divisions on the circular scale are observed. the diameter of the wire is