Home
Class 12
CHEMISTRY
For the galvanic cell : Ag|AgCl(s)),KC...

For the galvanic cell `:`
`Ag|AgCl(s)),KCl(0.2M)||KBr(0.001M),AgBr(s)|Ag,` calculate the `EMF` generated and assign correct polarity to each electrode for a spontaneous process after taking into account the cell reaction at `25^(@)C`.
`[K_(sp)(AgCl)=2.8xx10^(-10),K_(sp)(AgBr)=3.3xx10^(-13)]`

Promotional Banner

Similar Questions

Explore conceptually related problems

For the galvanic cell: Ag|AgCl(s)|KCl(0.2M)||KBr(0.001M)|AgBr(s)|Ag , calculate the EMF generated and assign correct polarity to each electrode for a spontaneous process after taking into account the cell reaction at 25^(@)C . [K_(sp(AgCl)) = 2.8 xx 10^(-10), K_(sp(AgBr)) = 3.3 xx 10^(-13)]

For the galvanic cell: Ag|AgCI(s)|KCI(0.2M)||KBr(0.001M)|AgBr(s)|Ag , calculate the EMF generated and assign correct polarity to each electrode for a spontaneous process after taking into account the cell reaction at 25^(@)C . [K_(sp(AgCI)) = 2.8 xx 10^(-10), K_(sp(AgBr)) = 3.3 xx 10^(-13)]

For the galvanic cell: Ag|AgCI(s)|KCI(0.2M)||KBr(0.001M)|AgBr(s)|Ag , calculate the EMF generated and assign correct polarity to each electrode for a spontaneous process after taking into account the cell reaction at 25^(@)C . [K_(sp(AgCI)) = 2.8 xx 10^(-10), K_(sp(AgBr)) = 3.3 xx 10^(-13)]

For the galvanic cell : Ag|AgCl(s), KCl (0.2M)||KBr(0.001M), AgBr(s)|Ag, calculate the EMF and assign correct polarity to each electrode for a spontaneous process after taking into account the cell reaction at 25^(@)C . Given : K_(sp)(AgCl)=2.8xx10^(-10), K_(sp)(AgBr)=3.3xx10^(-13)

For galvanic cell: Ag|AgCI(s), KCI(0.2M|| KBr (0.001M), AgBr(s)|Ag Calculate EMF generated and assign correct polarity to each electorde for spontaneous process after taking into accunt the celol reaction at 25^(@)C . K_(sp) AgCI = 2.8 xx 10^(-10), K_(sp)AgBr = 3.3 xx 10^(-3) .

For galvanic cell, Ag|AgCl(s),CsCl(0.1M)||CsBr(10^(-3)M),AgBr(s)|Ag. Calculate the EMF generated and assign correct polarity to each electrode for spontaneous or exergonic process at 25^(@)C . Given :. K_(sp) of AgCl=3.0xx10^(-10),K_(sp) of AgBr=4.0xx10^(-13) .

For galvanic cell, Ag|AgCl(s),CsCl(0.1M)||CsBr(10^(-3)M),AgBr(s)|Ag. Calculate the EMF generated and assign correct polarity to each electrode for spontaneous or exergonic process at 25^(@)C . Given :. K_(sp) of AgCl=3.0xx10^(-10),K_(sp) of AgBr=4.0xx10^(-13) .

For galvanic cell, Ag|AgCl(s),CsCl(0.1M)||CsBr(10^(-3)M),AgBr(s)|Ag. Calculate the EMF generated and assign correct polarity to each electrode for spontaneous or exergonic process at 25^(@)C . Given :. K_(sp) of AgCl=3.0xx10^(-10),K_(sp) of AgBr=4.0xx10^(-13) .