STATEMENT - 1 If the accelerating potential in an X - rays tube is increased, the wavelength of the characteristic X- rays do not change . STATEMENT -2 When an electron beam strikes the target in an X- rays tube, part of the kinectic energy is converted into X - rays energy .
A
Statement - 1 is true , Statement -2 is true Statement -2 is a correct explanation for Statement - 1
B
Statement - 1 is true , Statement -2 is true Statement -2 is a NOT a correct explanation for Statement - 1
C
Statement - 1 is true , Statement -2 is false
D
Statement - 1 is false , Statement -2 is true
Text Solution
Verified by Experts
The correct Answer is:
B
(b) Statement 1 : The wavelength of characteristic X- rays depends on the of atome of which the targetmate meterial is mode , it does not depend on the accelerating potential therefore statement 1 is true Statement 2 : when an electric beam strikes the target in an X- rays tube , part of the kinetic energy is converted into X- ray energy .This statement is true But statement 2 does not explain statement 1
SUNIL BATRA (41 YEARS IITJEE PHYSICS)|Exercise Comprehension Based Questions|2 Videos
MOVING CHARGES AND MAGNETISM
SUNIL BATRA (41 YEARS IITJEE PHYSICS)|Exercise MCQs(d )|1 Videos
Similar Questions
Explore conceptually related problems
Statement-1 If the accelerating potential in an X-ray tube is increased, the wavelength of the characterstic X-rays do not change. because Statement-2 When an electron beam strikes the target in an X-ray tube, part of the kinetic energy is converted into X-ray energy.
The characteristic of the electrons striking the target in an X-ray tube that, determines the intensity of X-rays is
The operating potential in an x-ray tube is increased by 2%. The percentage change in the cut off wavelength is
STATEMENT-1: In an X-ray tube, the wavelengths of the characteristic X-rays depends on the metal used as target. STATEMENT-2: Metals atomic numbers are best suited for the production of X-rays
In an X - rays tube , the intensity of the emitted X - rays beam is increased by
In X -rays tube the accelerating potential at the anode is V volt, The minimum wavelength of the emitted X -rays will be.
The kinetic energy of electrons that strike the target is increased , then the cut-off wavelength of continuous X-rays spectrum
A: If the accelerating potential in an X- ray machine is decreased, the minimum value of the wavelength of the emitted X -rays gets increased. R: The minimum value of wavelength of the emitted X-rays is inversely proportional to the accelerating potential.
The X- rays beam coming from an X- rays tube will be
If the cathode - anode potential difference in an X - ray tube be 10^(5) V , then the maximum energy of X - ray photon can be
SUNIL BATRA (41 YEARS IITJEE PHYSICS)-MODERN PHYSICS-MCQ (One Correct Answer