The transformation ratio in the step-down transformer is

A

`1`

B

greater than one

C

less than one

D

the ratio greater ot less than one depends on the other factors

Text Solution

Verified by Experts

The correct Answer is:
B

Transformation ratio `k=(N_(s))/(N_(p))=(v_(s))/(V_(p))`
for step-up transformations, `N_(s)gtN_(p)i.e.V_(s)gtV_(p)`, hence `kgt1.
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    A2Z|Exercise Problems On Mixed Concepts|37 Videos
  • ELECTROMAGNETIC INDUCTION

    A2Z|Exercise Section B - Assertion Reasoning|31 Videos
  • ELECTROMAGNETIC INDUCTION

    A2Z|Exercise Inductor Circuits|31 Videos
  • ELECTRIC POTENTIAL & CAPACITANCE

    A2Z|Exercise Section D - Chapter End Test|29 Videos
  • ELECTROMAGNETIC WAVES AND COMMUNICATION SYSTEM

    A2Z|Exercise Section D - Chapter End Test|30 Videos

Similar Questions

Explore conceptually related problems

The transformation ratio in the step -up transformer is

What is transformation ratio ?

What is increase in step-down transformer?

A thermal power plant produed electric power of 600kW at 4000V, which is to be transported to a place 20 km away form the power plant for consumer's usage. It can be transported either directly with a cable of large current carrying capacity or by sing a combination of step-up and step-down transfprmers at the two ends. THe drawback of the direct transmission is the large energy dissipation. In the method wsing transformers, the dissipatiion is much smaller. In this method a step-up transformers is used at the plant side so that the current is reduced to a smaller value. At the consumers'end, a step-down transformer is used to supply power to the consumers at the specified lower voltage. It is reasonable to assume that the power cable is purely resostive and the transformers are ideal with power factor unity. All the currents and voltagementioned are values. In the method using the transformers assume that the ratio of the number of turns in the primary to that in the secondary in the step-up transformer is 1:10 if the power to the consumers has to be supplied at 200V, the ratio of the number of turns in the primary to that in the secondary in the step-down transformer is

The transformer ratio of a step up transformer is

Which of the following equantities remain constant in a step- down transformer ?

A2Z-ELECTROMAGNETIC INDUCTION-Applications Of Emi
  1. A transformer is employed to

    Text Solution

    |

  2. What is increase in step-down transformer?

    Text Solution

    |

  3. The transformation ratio in the step-down transformer is

    Text Solution

    |

  4. In a transformer 220 ac voltage is increased to 2200 volts. If the nu...

    Text Solution

    |

  5. The ratio of secondary to the primary turns in a transformer is 3:2. I...

    Text Solution

    |

  6. The primary winding of a transformer has 100 turns and its secondary w...

    Text Solution

    |

  7. A step-down transformer is connected to 2400 volts line and 80 amperes...

    Text Solution

    |

  8. A loss free transformer has 500 turns on its primary winding and 2500 ...

    Text Solution

    |

  9. An ideal transformer has 100 turns in the primary and 250 turns in the...

    Text Solution

    |

  10. A transformer is employed to reduce 220V to 11V. The primary draws a ...

    Text Solution

    |

  11. in a step-up transformer, the turn ratio is 1:2A leclanche cell (e.m.f...

    Text Solution

    |

  12. A 100% efficient transformer has 100 turns in the primary and 25 turns...

    Text Solution

    |

  13. In a lossless transformer an alternating current of 2 amp is flowing i...

    Text Solution

    |

  14. A transformer connected to 220 volt line shows an output of 2A at 1100...

    Text Solution

    |

  15. The coils of a step down transformer have 500 and 5000 turns. In the ...

    Text Solution

    |

  16. A power transformer is used to step up an alternating e.m.f. of 220 V ...

    Text Solution

    |

  17. A step up transformer connected to a 220V AC line is to supply 22 kV f...

    Text Solution

    |

  18. A step-down transformer is connected to 2400 volts line and 80 amperes...

    Text Solution

    |

  19. The number of turns in the primary coil of a transformer is 200 and th...

    Text Solution

    |

  20. The primary winding of transformer has 500 turns whereas its secondary...

    Text Solution

    |