The turn ratio of a transformers is given as `2:3`. If the current through the primary coil is `3 A`, thus calculate the current through load resistance

A

`1A`

B

`4.5A`

C

`2A`

D

1.5A`

Text Solution

Verified by Experts

The correct Answer is:
C

As `(I_(p))/(I_(s))=(n_(p))/(n_(s))implies(3)/(I_(s))=(3)/(2)impliesI_(2)=2A`.
Promotional Banner

Topper's Solved these Questions

  • ELECTROMAGNETIC INDUCTION

    A2Z|Exercise Problems On Mixed Concepts|37 Videos
  • ELECTROMAGNETIC INDUCTION

    A2Z|Exercise Section B - Assertion Reasoning|31 Videos
  • ELECTROMAGNETIC INDUCTION

    A2Z|Exercise Inductor Circuits|31 Videos
  • ELECTRIC POTENTIAL & CAPACITANCE

    A2Z|Exercise Section D - Chapter End Test|29 Videos
  • ELECTROMAGNETIC WAVES AND COMMUNICATION SYSTEM

    A2Z|Exercise Section D - Chapter End Test|30 Videos

Similar Questions

Explore conceptually related problems

Calculate the current flows through resistance 2Omega .

The number of turns in primary and secondary coils of a transformer is 50 and 200, respectively. If the current in the primary coil is 4 A, then current in the secondary coil is

Current passing through 3 Omega resistance is

Turn ratio of a step-up transformer is 1 : 25. If current in load coil is 2A, then the current in primary coil will be :

In a stepup transformer, the ratio of number of turns in primary and secondary coils is 1 : 10 . What voltage will develop in the secondary if the primary is connected to 220 V mains ? If the current drawn from the secondary is 2A, calculate the current through the primary

The transformer ratio of transformer is 10 : 1 . The current in the primary circuit if the secondary current required is 100 A assuming the transformer be ideal, is

In the network shown calculate current through the cell (I_1) and the current I_(2) through the 2 R resistance.

An ideal transformer has primary and secondary coils of 200 turn and 40 turns respectively. If the current in the primary coil is 3A. Then the value of current in the secondary coil wil be

A2Z-ELECTROMAGNETIC INDUCTION-Applications Of Emi
  1. A step-down transformer is connected to main supply 200V to operate a ...

    Text Solution

    |

  2. The number of turns in primary and secondary coils of a transformer ar...

    Text Solution

    |

  3. The ratio of secondry to the primary turns in a trans is 9:4. If the ...

    Text Solution

    |

  4. A transformer has turn ration 100//1. If secondary coil has 4amp curr...

    Text Solution

    |

  5. In a step-up transformer the turn ratio is 1:10. A resistance of 200 o...

    Text Solution

    |

  6. In a step-up transformer the voltage in the primary is 220 V and the c...

    Text Solution

    |

  7. A transformer has 100 turns in the primary coil and carries 8A current...

    Text Solution

    |

  8. An ideal transformer has 500 and 5000 turn in primary and secondary wi...

    Text Solution

    |

  9. In a primary coil 5A current is flowing on 220 volts. In the secondary...

    Text Solution

    |

  10. A step up transformer has transformation ration 5:3. What is voltage i...

    Text Solution

    |

  11. In a step up transformers, 220V is converted into 200V. The number of ...

    Text Solution

    |

  12. The output voltage of a transformer connected to 220 voltl line is 110...

    Text Solution

    |

  13. In a region of uniform magnetic induction B=10^(2) tesla, a circular c...

    Text Solution

    |

  14. In a transformer, the number of turns in primary and secondary are 500...

    Text Solution

    |

  15. In an inductor of inductance L=100mH, a current of I=10A is flowing. T...

    Text Solution

    |

  16. The turn ratio of a transformers is given as 2:3. If the current throu...

    Text Solution

    |

  17. A transformer with efficiency 80% works at 4 kW and 100 V. If the seco...

    Text Solution

    |

  18. In a step up transformer, if ratio of turns of primary to secondary is...

    Text Solution

    |

  19. If a coil made of conducting wires is rotated between poles pieces of ...

    Text Solution

    |

  20. A step-down transformer is used on a 1000 V line to deliver 20A at 120...

    Text Solution

    |